fire door holes
”
RELATED FAQS
Question
Answer
What is the largest diameter hole that Steelcraft can provide for viewer preps?
Resolution:
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations.Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers must ...:
Will a 25R-L cover the door prep from a 18-R-L?
Resolution:
The (4) center case mounting holes are in the same location but there are some small modifications that will be needed like the 3/4" dia. hole at device CL for the main cam clearance shown o...:
Will new 3347A fit in the old 3347 door prep?
Resolution:
To replace an old 33/3547 exit device with a new 33/3547A exit device the door would need to be modified. The new device will cover any changes to the door prep. See attached templates for retrof...:
What is the ANSI A115.1 Government 86 Door Prep for the L9000 lock?
Resolution:
See image, ANSI A115.1 Mortise Lock Prep This door prep requires the N escutcheon with the L283-029 spacer kit to keep the springcage from falling into the door.&nbs...:
What arm can I use for the old LCN 4030/4130 closer?
Resolution:
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit There is no closer that can replace the old 4030 series closer with the exa...:
Why are there two different bore sizes on the templates for the B500 and B600 deadbolts?
Resolution:
The bore size is dependent on the function of the deadbolt. Some functions can be installed into a 1 1/2" or 2 1/8" bore while others require 1 1/2" only. You need to reference the dead...:
Does Falcon make a plate to cover holes when the door is prepped wrong?
Resolution:
These items are not available from Schlage or Falcon. There are third party companies such as Don-Jo or Pro-Lok that manufacture cover plates.:
Do we make a blank trim plate to replace an existing trim?
Resolution:
We have several blank trims listed in the price book to cover existing trim prep in door. DEVICE EO TRIM 22 230EO 88 880EO 98/99 990EO or 996EO* 33A/35A Rim, 33/3...:
What LCN closer is comparable to the Norton 7500?
Resolution:
The Falcon SC71 is an exact replacement for the Norton 7500. The LCN 1460 or 4040 Series closers could be used, the mounting hole pattern is different.:
Are astragals required on fire doors?
Resolution:
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...:
Can protective plates be attached to fire rated door?
Resolution:
Yes, Steelcraft doors we are approved up to 48" in height or not to exceed a total 2304 square inches per face. Protective plates are usually flat sheets of metal or plastic applied to one or both...:
Can decorative metal panels be installed over the entire surface of fire doors?
Resolution:
Decorative metal panels can only be attached if the panel manufacturer is UL listed in UL’s category GVUZ. All installation, sizes and hourly ratings are in accordance with that manufacturers” ...:
What are Hold Open Closers & Magnets?
Resolution:
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...:
Do the 390+ and 390DEL have the same footprint?
Resolution:
Yes, but the 390DEL is limited to push side of out swing door.:
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
What are the dimensions of the SC70 footprint
Resolution:
The measurements from center line to centerline of the mounting holes are 2-3/8" x 6-3/4".:
Can the 9949 CVC be used on fire rated wood doors?
Resolution:
There are several door manufacturers that have achieved a 90 minute UL Fire listing as shown. Von Duprin CVC with Marshfield Wood Door: Von Duprin is pleased to announce that Marshfield ...:
Can a magnet, or sentronic device, be released and close the door from a button at a desk?
Resolution:
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiri...:
Can a 3 hour A labeled Fire Door be prepped for multiple glass lights?
Resolution:
A fire rated door for 3 hours can have one glass light maximum: 100 square inches and must have an approved glass (Firelite type) Max glass size cannot exceed 12" in width or 33" in height. Wi...:
What Steelcraft doors can be prepped for a Von Duprin InPact device?
Resolution:
Steelcraft L-Series and T-Series doors are available (as an option) factory prepared for the Von Duprin InPact exit device. :
Is GrainTech available fire rated?
Resolution:
GrainTech® is available with very broad fire ratings.The option of GrainTech® does not affect the fire rating of the door.Fire ratings depend on the door series, hardware and applications.For all f...:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Which strike do you use with an XP98/99 device?
Resolution:
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.:
What are the different door cores available?
Resolution:
The five most common cores are honeycomb, polystyrene, polyurethane, steel stiffened, and temperature rise. Honeycomb core doors are used for interior and exterior openings where high thermal...:
Do any products offered by Steelcraft contain asbestos?
Resolution:
Steelcraft doors and/or frames do not contain any asbestos. Steelcraft did use asbestos in the following products: Steelcraft S16-Series stile and rail door with flush panel and UL fire door l...:
What would cause an EL device to pull and release?
Resolution:
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...:
Does LCN still make a closer that has the built in smoke detector?
Resolution:
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detector...:
What is a U-Factor?
Resolution:
The U-Factor, R-Value and K-Thermal Rating are measurements of thermal transmission through building products. U-Factor: Overall co-efficient of heat transmission passage through a built-up panel...:
What is the maximum door size for ITS/WHI fire rated doors?
Resolution:
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...:
Where is the Fire Label located on a door and a frame?
Resolution:
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...:
Are Steelcraft doors and/or frames fire rated?
Resolution:
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...:
Is a 20 minute label door a real fire door?
Resolution:
The 20 minute Fire Rating is a valid label and are commonly referred to as "Smoke and Draft control door assemblies". Depending on the local fire code and the openings's applica...:
What cores are offered for insulated doors?
Resolution:
Insulated Core Options: Steelcraft L-Series doors are available with the following 2 optional insulated cores: Polystyrene slab - this core is available in non fire rated and fire rated doors...:
What is the maximum glass light size on a 90 min (1 1/2 hour) fire rated door?
Resolution:
Standard listed wire glass: one (1) light with 100 in2 per door leaf max.Firelite or other appropriately listed glass:• FM maintains one (1) light with 100 in2 per door leaf max.• UL &...:
What is the max rating available on an full glass (FG) door?
Resolution:
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design. A14-Series door construction: Max fire rating is 20 minute. UL label only FG must use Over-Lapping Stee...:
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
What is GrainTech?
Resolution:
GrainTech® is a Steelcraft door option which provides a wood grained pattern which is embossed into both face sheets of the door. GrainTech doors are factory stained and top coated with a cle...:
What is the maximum glass light size on a 3 hour (180 minute) fire rated door?
Resolution:
Maximum glass light sizes for 3 hour fire doors is as follows: Wire glass - not approved for use in 3 hour fire doors. Ceramic glass: UL & ITS/WH allow one (1) light with 100 square inc...:
Are intumescent seals or gaskets required on fire rated steel doors?
Resolution:
Intumescent seals or gaskets are not required on fire rated steel doors. Generally speaking, the requirement for intumescent seals or gaskets are a function of the individual manufacturers’ listi...:
Can 5100 electric strikebe used on fire rated door?
Resolution:
The Von Duprin 5100 electric strike is not for fire rated applications.:
Is the Von Duprin Guard-X exit device fire rated?
Resolution:
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. :
Is the Von Duprin 6223 fire rated for pairs of wood doors?
Resolution:
The 6223-FSE electric strike is fire rated for pairs of wood doors, but check with wood door manufacturer to see if they have been approved for this application.:
Fire Rating for AD and CO locks
Resolution:
The AD and CO locks both have a 3 hour fire door rating. Please see URL for more info. UL Fire Rating List:
Is the 3130 Series closer Fire Rated?
Resolution:
The 3130 Series closer is UL listed- Fire Rated (UL-10C) for up to 3 Hr. The Door and Frame Manufacturer needs to be contacted to verify their Door/Frame rating would not be ...:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
Can doors be prepared for raceways in the factory?
Resolution:
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 3/4" ID steel...:
Can Steelcraft doors be prepped for the 98/9949 Concealed Vertical Cable Exit Device?
Resolution:
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.L, B, CE, T and CE-Series doors are available factory preparedDoor prepa...:
What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
Resolution:
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts. This may NOT be used on Fire Rated openings.:
Can wood doors be used with with double egress frames?
Resolution:
Yes, wood doors can be used and installed in most hollow metal frame applications including FE-Series and DE-Series Double Egress frames. Caution - For fire rated applications the wood door manufa...:
Are the Falcon SC Series door closers fire rated?
Resolution:
Yes, the Falcon SC Series closers have a UL listing.:
What is the maximum door size for UL fire rated doors?
Resolution:
Maximum UL Fire Rated door sizes are as follows:A-Series:4' 0" X 8' 0" single door8' 0" X 8' 0” double door or pairsB-Series4' 0" X 10' 0" single door8' 0" X 10' 0” double door or pairsCE-Series:3'...:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...: