Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
883
884
885
886
887
»
Question
Answer
Can the 8200 Falcon operator be used with the 8310-3889 safety sensor kit?
Resolution:
The 8200 Falcon operator is not compatible with the 8310-3889 kit .If an 8310-877 header mount safety sensor is needed with an 8200 Falcon operator, follow the standard wiring shown in the 8310-877...:
Can the 8200 Falcon operator be used with an LO-21P device from BEA?
Resolution:
Unfortunately, the 8200 Falcon operator is not compatible with an LO-21P module.:
Does the 8310-877 HMSS / Bodyguard have different wire colors for the 8310-846 harness if it’s purchased directly from BEA?
Resolution:
Yes, the BEA harness and LCN harness are different. The LCN version is unique as it has a connector on one end that plugs directly into P1 for the Sr. Swing whereas BEA’s version has no connector f...:
What is the clearance required at 90 degrees, between the door and wall for a pull side mount using the 6440XP?
Resolution:
The 6440XP protrudes off the door 3 3/4" so that would be the absolute minimum space needed for clearance in this mounting.:
Does the ALX have a drive in latch offering?
Resolution:
The ALX does NOT have a drive in latch offering. :
Is there a plug available to fill a hole in the door prep for the thumbturn on Schlage L9000 mortise locks?
Resolution:
For sectional trim, Schlage does not offer a plug to fill the thumbturn hole in the door prep for an L9000 mortise lock. The hole can be covered by switching to escutcheon trim wh...:
What cams are available with extended mortise cylinders?
Resolution:
When extending FSIC or conventional mortise cylinders, Schlage utilizes the old style non-modular two hole cams. B520-295 Corbin DL4000 B520-233 Corbing Russwin ML2200 ...:
Why is the 110NL cylinder assembly required with Von Duprin 22 and 98/99 series device NL-OP applications?
Resolution:
These applications use a rim cylinder, and a normal rim cylinder anchor plate that would be affixed to the push side of the door would interfere with the operation of the master cam on the back sid...:
Why is the 388NL cylinder assembly required with the Von Duprin 33A/35A Series exit devices for NL-OP applications?
Resolution:
This application requires the use of a rim cylinder, and an ordinary rim cylinder anchor plate would interfere with the components on the back of the exit device center case. The 388NL provides an ...:
What is the minimum door width when using the 4410HSA closer?
Resolution:
24 inch minimum door width.:
«