Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
689
690
691
692
693
»
Question
Answer
What are the details about 900-KL, 900 series power supply locks?
Resolution:
Cam locks for the 900 series (902/904/906/914) power supplies can be ordered with the power supply or as a separate item. The model number for the lock is 900-KL, and the part number is 44486...:
What is the part number for the set screw for the SL1/SK1 inside ligature trim?
Resolution:
The set screw part number for the inside SL1/SK1 ligature trim is L583-585.:
What is the part number for the hex nut for the 945 Falcon Cam Lock?
Resolution:
The hex nut part number for the 945 Falcon Cam Lock is 031100-000-30. :
Is The QEL Polarized?
Resolution:
No. The power wires to the QEL are not polarized:
Why is there a transient voltage suppressor included with my electric strike?
Resolution:
ANSI BHMA 156.13 has a provision for inductive kickback. Using the transient suppressor across the strike's solenoid wires allows this standard to be met. This would be most applicable ...:
When did LCN change the DPS Switch on the 2210DPS series closers from a 10.1 amps rated switch to one with an .1mA rated switch?
Resolution:
LCN changed the DPS switch on the 2210DPS series closers from a 10.1 amp rated switch to a .1mA rated switch on February 23rd, 2018.Photo of DPS switch as 2/23/2018 see here. Note the tr...:
Can a thumbturn cylinder be used on the L9453?
Resolution:
A thumbturn cylinder will not provide the intended operation. The L9453 requires the actual thumbturn hub to be rotated the additional 20° to unlock the outside lever once the deadbolt has be...:
What is the temperature range of the 4200 electric strike?
Resolution:
The 4200 electric strike has been tested by the supplier to: -35 to 65 degree Celsius (-31 to 149 degree Fahrenheit) The strike has also been tested to U...:
What size of the 94 impact device would be used on a 2'10" door?
Resolution:
The standard 94/95 device was designed to fit door openings from 2’-10” to 4’-0”, not net door sizes. Originally, the shorter version of the Inpact device was designed to fit door openings fro...:
Is there a part number for the Von Duprin plastic template?
Resolution:
900594-00 is the correct part number for the plastic template that ships with the 98/99 exit device:
«
689
690
691
692
693
»