Question
Answer
Can a Von Duprin or Falcon LX or RX switch be used to power a mag lock?
Resolution:
Using a Von Duprin monitor switch - such as RX or LX - to directly control mag lock power is not recommended.Monitor switches are normally used as signalling inputs to a power supply lo...:
Is the 940L trim compatible with older 94 and 95 series exit devices?
Resolution:
Yes, the 940L is backwards compatible with all 94 and 95 series exit devices. The master cam on the back of the exit device should be positioned so the half-moon cut out faces toward the lock...:
How does the ND73 function?
Resolution:
Lock can be locked or unlocked by the key on the outsidePush button on inside lever locks outside leverTurning the inside lever or closing the door will release the push buttonIf the outside lever ...:
How to Locate the Programming Sticker on Schlage Sense Lock?
Resolution:
All necessary codes are printed in the User Guide that comes with your lock. The programming code and default access codes are located on one sticker, while the HomeKit setup code is located on ano...:
Have the HL6/7/8 and HL6-9000 cover screws changed?
Resolution:
Cover screws for the HL6 are different depending on the date of manufacture. Manufactured since June 18th, 2018 Finished cover screws K110-020 (pack of 2 each K510-210, #8-3...:
Does the 2' 9927-F come with a fire lable?
Resolution:
Yes:
How to convert EL 98/99 to QEL ? Is it ok to use the modular conversion kit, or is QEL baseplate assembly required ?
Resolution:
A new QEL baseplate assembly is needed. The modular conversion kit needs the dogging rod to work. The EL baseplate being replaced does not have a dogging rod. :
Will the F-25-R work for a 9' tall door? The catalog says only good to 8'.
Resolution:
8' max height on UL fire rated F-25-R:
What is the weight load of a 5BB1 HW hinge?
Resolution:
Per the ANSI/BHMA specification that covers hinges, hinge testing is performed with a 150 lb door.Allegion does not publish test-to-failure data, as there are no standardized tests for such c...:
Can the LX switch be used with the XP exit device?
Resolution:
Standard Von Duprin LX switch kits are not compatible with the XP98/99 device.The LX switch in an XP device is mounted in the center case. It monitors the position of the rear portion of the ...:
«