Can the 284L-4 Strike be used with HH devices?
Resolution:
The 284L-4 is a bottom strike for some Von Duprin Panic Rated Surface Vertical Rod exit devices and is used when a threshold is present.The Von Duprin HH (Wind and Impact Rated) and HW (Wind only) ...:
Can you use the ND indicator in exterior applications?
Resolution:
The ND indicator was tested and approved for exterior applications. :
Is the 4510 closer available with a hold open arm?
Resolution:
There is currently one special (ST-2670) hold open arm available for the 4510 series. This special uses a standard, non-tamper proof hold open arm. This means it will no longer be suited for ...:
How are the Schlage L9000 locks with MLR handed?
Resolution:
The Schlage L9500 and L9600 mortise locks, with mortorized/electrified latch retraction, are handed in the same way as the L9000 locks. Handing screw must be on the “inside” side of the lock ...:
Does LCN and Falcon share the same spring stop block?
Resolution:
All LCN Spring cush blocks, except for the 1250 and 1450 series, are the same as the spring cush block that is used on the Falcon SC Closers Spring Stop Arms. Both the LCN 1250 and 1450 clos...:
Can you mount the 2210 in a 24” door leaf
Resolution:
You can use ST-2300-1 to a mount a 2210 high security closer in a 24” door leaf. Requires special arm and track, and special templating.:
What template do you use for the 4040SE mounted push side with a 18PA drop plate?
Resolution:
The template for mounting the 4040SE push side with a 4040SE-18PA drop plate is special template, ST-2844.:
Can you extend the antenna on the 865 receiver?
Resolution:
You can extend the antenna on the 865 receiver up to 3 times, in increments of 6 ¾”. 18-22AWG works best.:
Does the ND indicator thin door kits come with everything you need to mount ND indicators on a door less than 1-3/4"?
Resolution:
The ND indicator thin door kits come with a spacer for the non indicator side and a spacer for the indicator side. The spacers are all that are needed to mount existing standard ND's with ind...:
Is the Schlage L9000 mortise lock compatible with Falcon and Von Duprin mortise exit devices?
Resolution:
The Schlage L9000 Series mortise locks are NOT compatible with Falcon and Von Duprin mortise exit devices.Falcon mortise exit devices (25-M/F-25-M) use the 8500NL mortise lock.Most Von Duprin morti...:
«