Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
1182
1183
1184
1185
1186
»
Question
Answer
What is the length of the 2810-168 Slide?
Resolution:
The 2810-168 slide length is 11”. For OP arm template, see here.:
Is there a pull side mount Benchmark 9150 available?
Resolution:
The Benchmark 9150 is only available as a Push side mount. It is not available in a pull side mount.:
Can you order a 4040XP closer with the Backcheck Selector valve already screwed in?
Resolution:
You can order the 4040XP closer x ST-3068 to have the Backcheck Selector Valve already screwed in for parallel arm mounted applications. :
Can you mount the 4000T with the closer on a door and track on the wall?
Resolution:
You can use ST-2457 which reverses the mounting of the 4000T where the track is mounted to the wall in a pocket and the closer is mounted on the door. This is only for use on Standard Butt Hi...:
What is the difference between A2 pinning and A4 pinning?
Resolution:
Small format interchangeable cores (SFIC) have different pinning systems available to them. These pinning systems consist of specific sets of pin measurements, key cut depths, step increments...:
Can the 284L-4 Strike be used with HH devices?
Resolution:
The 284L-4 is a bottom strike for some Von Duprin Panic Rated Surface Vertical Rod exit devices and is used when a threshold is present.The Von Duprin HH (Wind and Impact Rated) and HW (Wind only) ...:
Can you use the ND indicator in exterior applications?
Resolution:
The ND indicator was tested and approved for exterior applications. :
Is the 4510 closer available with a hold open arm?
Resolution:
There is currently one special (ST-2670) hold open arm available for the 4510 series. This special uses a standard, non-tamper proof hold open arm. This means it will no longer be suited for ...:
How are the Schlage L9000 locks with MLR handed?
Resolution:
The Schlage L9500 and L9600 mortise locks, with mortorized/electrified latch retraction, are handed in the same way as the L9000 locks. Handing screw must be on the “inside” side of the lock ...:
Does LCN and Falcon share the same spring stop block?
Resolution:
All LCN Spring cush blocks, except for the 1250 and 1450 series, are the same as the spring cush block that is used on the Falcon SC Closers Spring Stop Arms. Both the LCN 1250 and 1450 clos...:
«