Does Steelcraft have a maintenance guide for their doors and frames?
Resolution:
Steelcraft does not have a maintenance guide for their doors and frames. Steelcraft follows the guidelines recommended by SDI (Steel Door Institute) in document 124-22. This guide can be found on t...:
Does Steelcraft offer a rabbeted door edge on their doors?
Resolution:
Rabbeted door edges are not available on Steelcraft doors. Steelcraft only offer beveled edges on most door series except the SL or SZ series doors which have square edges.:
Can you mount a 4040SE pull side with a 4" reveal on a total door system?
Resolution:
ST-3351 is used when trying to mount a 4040SE pull side with a maximum of a 4” reveal and a Total Door System. This will work with reveals between 2-11/16” and 4”. It uses a special DE a...:
What is the minimum and maximum reveal for a LCN 5010 closer with reg arm?
Resolution:
The minimum reveal is ¾" and the maximum reveal is 2" when using the 5010 closer with reg arm. :
Does the LCN 2210 closer have a Hold open option?
Resolution:
The LCN 2210(DPS) does not have a hold open / bump / hold open bump track available. The LCN Hold Open clip and bumper, will not fit into the 2210(DPS) track. Also, the 2210 arm will no...:
Where can i find LCN instruction sheets?
Resolution:
See here.:
Can the LCN 2800 concealed senior swing operator be used with pocket pivots or swing clear hinges?
Resolution:
The 2800 series operator cannot be used with pocket pivots nor swing clear hinges.These hinges have too much rotation and arm does not have enough travel in the door.:
What is the door range for the ALX170 single dummy trim?
Resolution:
The standard option for ALX170 is surface mount which will work on door thicknesses down to 1-3/8". With the thru-bolt option kit, the standard door range of 1-3/8" through 1-7/8" is supported...:
How to remove a split key construction insert from a conventional cylinder?
Resolution:
See the video “How to remove split key construction insert”. This instruction would also apply to Falcon conventional cylinders that a construction keyed using the split key or Block-O-Key met...:
Are monitoring switches available on L9000 series with XL13-439 key override?
Resolution:
L9000 series locks when ordered with the XL13-439 key override feature are not available with monitoring switch options: Request to Exit (RX), Latch Monitoring (LX), Door Position Switch (DPS), or ...:
«