Can the Falcon MA series be ordered for a Non-standard door thickness?
Resolution:
The Falcon MA series can be ordered for a door thickness up to a 2 1/2" thick door, this would need to be specified at the time of ordering, and how the lock is centered within the thickness.Thumbt...:
What is the part number for the redesigned ND80 chassis?
Resolution:
The introduction of the rigid lever springcage in March of 2023, led to a redesign of the keycam assembly and chassis spindle for the ND12, and ND80 functions.In these functions, the new rigid leve...:
What is the XL13-369?
Resolution:
XL13-369 is a special option that shortens deadbolt on L/LV9456 and L/LV9457. Shorter deadbolt is not long enough to project into the door frame but will activate the DM switch.:
Can the ND50 be converted to an ND80 by replacing parts?
Resolution:
There are 2 options to converting the ND50 to the ND80.Option 1:Inside Lever - 03-230 [lever design] [finish]Chassis - S00031721363-KITOption 2:Inside Lever - 03-230 [lever design] [finish]Chassis ...:
Is ligature resistant trim available on LV9000?
Resolution:
The LV series is not available with the SK1/SL1/HSLR trims due to the Vandlgard functionality.:
Is the Schlage L9453 Entrance office lock the same as the Falcon MA541 Entry/Office lock?
Resolution:
Despite having similar names these two locks are not interchangeable. The L9453 (ANSI F20) inside lever will retract the latch and deadbolt simultaneously, the MA541 (ANSI F21) will only retra...:
Can the Falcon MA571 Dormitory/Exit lock be used in place of the Schlage L9473 Dormitory/Bedroom lock?
Resolution:
Despite both locks containing the word “Dormitory” they will function differently.The L9473 (ANSI F21) does not feature simultaneous retraction the inside lever will only operate the latch and the ...:
Is there a special housing needed for the Schlage Everest SL Core?
Resolution:
The Schlage Everest SL core can be installed into any Schlage FSIC Mortise or Rim housing.:
How long is the LCN 3130 standard arm?
Resolution:
The total length of the 3130-3077T standard arm is 14.157”This arm is 13.125 inches from Centerline to Centerline:
What is the difference between a 5547L, a NY5547L, and a NYCA5547L?
Resolution:
Panic Rated Metal Door ApplicationsThe standard 5547L x 376L Panic Exit Device for Metal Doors has a minimum Lever height of 49 7/8" Above Finished Floor (AFF).The NY5547L x 376L Panic Exit Device ...:
«