Question
Answer
Will the N523-091 SFIC driver for the ND series work with the AD/CO series?
Resolution:
The ND series SFIC driver (N523-091) has a blade length of 0.97".The AD/CO series SFIC driver (23446347) has a blade length of 0.71":
Does LCN offer a double pole double throw activation device?
Resolution:
All LCN actuators are a single pole double throw switch, LCN does not offer a double pole double throw actuator.:
Can LCN drop plates be order with SRI?
Resolution:
LCN does offer SRI on drop plates. The plate will be stamped with SRI on the plate as well if it has SRI pre-finish.:
Does Steelcraft have an online ordering tool?
Resolution:
Steelcraft does have an online entry tool called OEW (Order Entry Works). This tool is for distributors of Steelcraft products only. If you are a distributor, please contact your local sales rep to...:
Installation troubleshooting guide for steel doors and frames?
Resolution:
Installation Trouble Shooting Guide 122-21 which can be found on the SDI website under Technical Data Series. See here. :
When you order the LCN sr swing header dress plate, part #9540-334-2, do you get one or two dress plates?
Resolution:
When ordering the LCN sr swing dress plate, 9540-334-2, you will get two dress plates, one for each end of the header, plus 8 mounting screws.:
Does Steelcraft have a maintenance guide for their doors and frames?
Resolution:
Steelcraft does not have a maintenance guide for their doors and frames. Steelcraft follows the guidelines recommended by SDI (Steel Door Institute) in document 124-22. This guide can be found on t...:
Does Steelcraft offer a rabbeted door edge on their doors?
Resolution:
Rabbeted door edges are not available on Steelcraft doors. Steelcraft only offer beveled edges on most door series except the SL or SZ series doors which have square edges.:
Can you mount a 4040SE pull side with a 4" reveal on a total door system?
Resolution:
ST-3351 is used when trying to mount a 4040SE pull side with a maximum of a 4” reveal and a Total Door System. This will work with reveals between 2-11/16” and 4”. It uses a special DE a...:
What is the minimum and maximum reveal for a LCN 5010 closer with reg arm?
Resolution:
The minimum reveal is ¾" and the maximum reveal is 2" when using the 5010 closer with reg arm. :
«