Answer
Is there any ST's for using a 4050A regular with PA arm (PA or pull side mounted) with wide throw hinges to get 180 degree door swing?
Resolution:
Unfortunately, LCN currently does not have any Special Templates for using the 4050A closer (PA or pull side mount) with wide throw hinges to get a 180 degree door swing.For PA mount - Soluti...:
Where on the door does the M490DE Signage get placed, is there Fire Marshall approved measurements?
Resolution:
This information would come only from the local Fire Marshall specific to each area. It will vary by juristiction.:
Are the 4010(T) and 4110(T) plastic covers the same?
Resolution:
The standard plastic cover for the LCN 4010(T) & 4110(T) series closers is the same cover. It is a non handed plastic cover. :
How do you identify the size of the LCN pneumatic 2610 closer?
Resolution:
Based on the age of the closer, there are multiple locations the size could be stamped on the 2610 body.It will either be located on the packing nut where you would typically find the date stamp or...:
What is the part # for the LCN green hex wrench?
Resolution:
LCN does offer the Green Hex wrench - part numbers as followsGHW1 for the Qty 1GHW12 for the Qty 12GHW100 for the Qty 100:
What SDI 100 Level/Model is the Republic DL series door?
Resolution:
SDI 100 Level/Model: • Level 1 Model 1 (Standard Duty, minimum 20 gauge, hollow steel composite) • Level 2 Model 1 or 2 (Heavy Duty, minimum 18 gauge, hollow steel composite) • Level...:
What thickness is available for Republic DE series doors?
Resolution:
1-3/4" (14 gauge = 1-13/16")1-3/8" Thick door - Polystyrene core only 6'8" door standard (2) 3.5" hinges, (1) CH lock prep (2-1/8" Bore x 2-3/4" Backset/1" x 2-1/4" Edge) fire Rated 6'8" requ...:
What published standards do Republic DE Doors adhere too?
Resolution:
A. ANSI A250.8 (SDI 100) - Recommended Specifications - Standard Steel Doors & Frames; Steel Door Institute.B. ANSI A250.4 - Test Procedure & Acceptance Criteria for Physical Endurance for ...:
Is the Republic DL series door handed?
Resolution:
Handing Design – Non-handed standard (Optional handed):
Does the Republic DL series door come standard with a universal hinge prep?
Resolution:
Universal Standard/Heavy Weight Hinge – Hinge fillers are used allowing for easy modification from heavy to standard weight hinge prep:
«