How do you get the digital read out to light up on the Senior Swing Control Box?
Resolution:
There is a total of 4 red buttons on the front of the Senior Swing control box. To turn on the display, press and hold any 2 of the 4 red buttons at the same time for approximately 3-5 seconds. Y...:
Do all Senior Swing operators come with the Push-N-Go feature?
Resolution:
All Senior Swing models are heavy duty operators and have the Push-N-Go (PNG) feature. This feature is a programmable function in the control module. The PNG settings are:&nb...:
Where does the 8310-877 safety sensor attach to the Senior Swing controller?
Resolution:
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...:
What is the part number for the Senior Swing control box?
Resolution:
The Senior Swing Series changed to the "Digital" control box in Sept. of 2006.:
Can you use a Senior Swing controller as a replacement for an obsolete Mid Swing controller?
Resolution:
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box...:
What wires are the activation inputs for the Senior Swing?
Resolution:
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. ...:
Is the 9500 Series Senior Swing handed?
Resolution:
The Senior Swing "control box" is not handed. All Senior Swing motor "gearboxes" are handed, both the 2800 Series concealed and 9500 Series surface mounted operators. The 2800 Series "concealed a...:
Why does a Chexit device blink once then powers down?
Resolution:
If Chexit device LED blink once when you turn the unit on, the External inhibit green wire is not by passed or not connected to the access control normally closed contact. For devices sh...:
Why would the controller on my 4600 (4630/4640) have no lights on display when powered with 120 VAC?
Resolution:
Verify that the 120VAC is present at the controller (measure 120VAC on the 2 wire gray cable from I/O board to controller -- red/black wires in gray cable). If present, but no lights on the contr...: