frame in existing masonry wall
”
RELATED FAQS
Question
Answer
What is a Drywall Throat Filler?
Resolution:
Drywall Throat Fillers are used when wall thickness is between 1/8” (3mm) to 1/4” (6mm) less than the frame throat dimension, throat filler section(s) can be used to fill the gap, assuring the prop...:
Why do frames rust out fast?
Resolution:
Excessive premature frame rusting is caused by improper jobsite installation practices and most likely caused by the following circumstances: :
What is the maximum glass light size available on a 20 minute sidelight frame?
Resolution:
On fire rated transom and/or sidelight frames and fire rated window frames, Steelcraft labeling procedures only control the O/A width and/or height of the frames based on wall condition. The amount...:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
What is the purpose for using a 12 gage head reinforcement?
Resolution:
Purpose: When there is concern for the weight of overhead wall construction, or, when multiple surface applied hardware components are being used. This continuous channel has the ability to spre...:
Does wall board have to extend into the throat of a fire rated frame?
Resolution:
:
Can Drywall Slip-on frames be welded?
Resolution:
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installa...:
Can steel frames be installed after the wall board is installed in stud wall applications?
Resolution:
DW and K-Series frames are designed to slip onto a stud wall after the wall is finished (painted, wall papered, etc).Walls can be either wood stud or steel studUsed only for interior appl...:
Can out of plumb (twisted) frames be adjusted?
Resolution:
Out of plumb (also referred to as twisted) frames usually cannot be adjusted."Out of Plumb or Twisted frames (or jambs)" is a condition created by improper wall construction and/or improper in...:
Are adjustable base anchors provided with frames that are prepped for existing opening anchors?
Resolution:
No, an adjustable base anchor is not supplied on frames with existing opening anchors. The anchor design for use in existing masonry walls, is a pierce and dimple in the frame soffit for 3/8"...:
Does Steelcraft have frame installation instructions?
Resolution:
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documentsClick here to get the updated link to the Steelcraft Shop M...:
What is a Pocket Door Frames?
Resolution:
POCKET DOOR FRAME: A frame designed to allow a door to slide inside a pocket located within the cavity of a wall. The hinge jamb of the frame is replaced with a 2 piece jamb without a stop. I...:
What is the rough opening in walls for frame installations?
Resolution:
For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...:
What is the maximum frame size for a label transom and sidelight frame?
Resolution:
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes).In masonry wall application the maximum is 13'6" x 12'2"In stud wall application the maxi...:
What is a drywall slip-on frame?
Resolution:
Drywall Slip-on Frame is an industry term describing a 3 sided frame designed to be installed on a wall composed of steel or wood studs with gypsum board or other facing material and is i...:
Can an additional jamb anchor be used as a base anchor on fire rated frames?
Resolution:
Yes, an additional jamb anchor can be used at the bottom of the frame in lieu of the typical (adjustable or weld-in) base anchor in fire rated frames. This is limited to the anchor designed for...:
What frame profile variations are available on fire rated transom sidelights and window?
Resolution:
Elevation frames are available in: F-Series (F16 or F14) FN-Series (FN16 or FN14) MU-Series (MU16, MU14) Additional parameters of the frame components: Perimeter (Head and Jambs) Frame: ...:
Are Steelcraft doors and/or frames fire rated?
Resolution:
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...:
Can "toed in" or "toed out" jambs be adjusted?
Resolution:
This condition (toed in or toed out jambs) is usually not found until the door is installed.Frames which have toed in or toed out jambs have been installed out of tolerance.It is the responsibility...:
Why are frames grouted?
Resolution:
Grouting frames is: A process done in the field during hollow metal frame installation The internal cavity of the frame is fill with masonry or mortar It is intended to mainly provide ...:
What is the difference between the DW-Series and K-Series frames?
Resolution:
Both the DW and K-Series frames are identical with the exception of the base anchoring. Both the DW and K-series frames are supplied with a field adjustable compression anchor in each jamb locate...:
What is the difference between the FE and DE-Series frames
Resolution:
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...:
What causes excessive pinhole rust to start showing up on steel frames?
Resolution:
CAUTION must be used in investigating this problem - In most cases, excessive field rusting of products is caused by improper storage at the jobsite. That situation must be validated prior to refus...:
Can out of square frames be adjusted?
Resolution:
It is the responsibility of the installing contractor to install all material in accordance with SDI or HMMA installation standards and tolerances. Out of square frames which are installed out...:
What is ASTM E-119?
Resolution:
ASTM E-119 is a test standard for walls, partitions and floor or roof systems: This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames.As...:
Can DW/K frame series be used in high traffic areas?
Resolution:
DW/K-Series frames (Drywall Slip-On) are not recommended for installation in high traffic areas. DW/K-Series frames are installed in interior stud walls after the wall board is installed and ...: