do senior swing operators require auxilary stops

RELATED FAQS

Question
Answer
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
 EL devices are wired to the Senior Swing, using the P10 (761465) cable.  Connect the "GRAY" wire to the SC terminal on the 900-2RS card in the Von Duprin Power Supply and the "VIOLET" wire to the ...
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...
All Senior Swing models are heavy duty operators and have the Push-N-Go (PNG) feature.  This feature is a programmable function in the control module.  The PNG settings are: Off, On, or FD (fixed)...
How to Order: The Senior Swing header is ordered by the width of the door(s). The measurement from inside jamb to inside jamb of the frame. If the Senior Swing header is ordered the wrong length, ...
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...
The Senior Swing operator has a 24VAC output , rated at 1.5 Amps.
The ES Filter started to ship with these units (Senior Swing/Benchmark/Falcon) on 4/22/2013.  The ES Filter kit will help eliminate line noise from an Electric Strike if used. 
On the Senior Swing, if you have line noise from a strike the unit will go into an Error Code on the Control Box (Er14) and will not operate.  Adding the ES Filter, which is a diode, will eliminate...
On the Benchmark and Falcon, if there is line noise from a strike then the unit will lose it's hold open time.  Adding the ES Filter, which is a diode, will resolve this issue and the unit will hol...
The 9550 series Senior Swing WILL NOT work on a pair of doors with auto flush bolts. The 9560 series Senior Swing and a sequence module are required when used on an pair of door with auto flush b...
A Senior Swing operator can be hard to open manually if "Power Boost" feature is turned on, and programmed to the Cn (continuous) setting. To make the door easy to open manually, turn the "Power Bo...
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...
The Senior Swing has an optional (plug in) Off/Auto/Hold Open switch available. The 8310-806R (rocker switch), or 8310-806K (key switch). CANNOT use switch by others, requires a special (center - n...
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...
The Senior Swing 9500 or 2800 series operator is designed to for "High Traffic - High Abuse" areas.
The Senior Swing Series used to have a 2 gearbox options, a "standard force" (15 lbs) and a "RF - reduced force" (11 lbs). In November 2009 RF option was eliminated and we made the standard gearbox...
The 9550 Sr. Swing is for a simultaneous pair door opening. There is 1 control box with 2 gearboxes that opens both doors together. Uses the 9559-982 companion cable. The 9560 Sr. Swing is for an ...
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box with...
The Senior Swing control box is ordered as a 95xx-3462. Example - 9530-3462, 9540-3462.
The Senior Swing Series changed to the "Digital" control box in Sept. of 2006.
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. This harness p...
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.
The Senior Swing series operator would be the LCN equivalent to the Horton 4000 series operator.
The 9542 is the single door operator that mounts on the "push side" of the opening with a REG arm. The 9531 is the single door operator that mounts on the "pull side" of the opening with a STD arm...
For Allegion's recommendation see here.
The Senior Swing "control box" is not handed. All Senior Swing motor "gearboxes" are handed, both the 2800 Series concealed and 9500 Series surface mounted operators. The 2800 Series "concealed a...
The 4600 Series operator does not have a Push N Go feature. The LCN operators with a Push N Go feature are the Senior Swing, Benchmark, and the Falcon 8200 series.
The 8310-845 Timer/Sequencer is required to sequence two Senior Swing operators. The 8310-845 will need to be programmed to "Function 65" for the sequencing feature.
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before coming completely closed. T...
The older model Senior Swing came with 2 spring options. The "standard force" spring required 15 lbs of manual  opening force, and reduced force "RF" required 11 lbs of manual opening force.  All S...
To convert a Senior Swing 9550 to a 9560: Remove the companion harness (9550-982) from one of the motor/gearboxes in the 9550. Install a second control box, and connect it to the motor/gearbox t...
The Senior Swing will work with Cam Lift Hinges as a PUSH SIDE MOUNT 9542/9553/9563 only. Maximum 3/4" lift. Maximum 15 pounds force to push door up the Cam Lift Hinge. Cam Lift Hinges WILL NO...
The manual opening force to required to open a Sr Swing operator is approximately 11-12 lbs.
The 4600 is designed for an opening with (MOSTLY) manual traffic, and the (OCCASIONAL) automatic activation. The Senior Swing is designed for an opening with (MOSTLY) automatic activation, and (OC...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors.  Both units contained within the same Senior Swing header. To order a paired operator with a 2810 on&nb...
There is a total of 4 red buttons on the front of the Senior Swing control box. To turn on the display, press and hold any 2 of the 4 red buttons at the same time for approximately 3-5 seconds. Y...
When installing the arm; the gearbox shaft  and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install the header and door brac...
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/9563) have a 12...
To convert a 9530 to an 9540 you need to purchase the 9540-3077 REG push arm assembly. To convert a 9540 to an 9530 you need to purchase the 9530-3077 PLCM pull arm/track assembly.
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...