Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
852
853
854
855
856
»
Question
Answer
What are the differences between S76806 and S76816 Falcon part numbers?
Resolution:
Part number S76806 are spindles used with levers on standard door thickness of 1 3/4 to 1 7/8" or knobs with a door thickness of 1 7/8 to 2 1/2". Part number S76816 are spindles used for...:
What is the length of the C977 cylinder?
Resolution:
The length of the C977 cylinder is 1 1/8". :
What does the Schlage Cylinder Suffix G mean?
Resolution:
The G suffix for Schlage means the lock will be prepped for SFIC and a Schlage Restricted SFIC core will be provided in either the Schlage Everest B or Schlage Everest 29R Keyway by request. ...:
What is the diameter of the B560P housing and collars?
Resolution:
Here are the diameters of various B560P components: The ring (lip) around the anti-pry shield is approximately 2.523" in diameter (widest overall point of the B560 components) The cu...:
What does Q mean in the part number for HL6?
Resolution:
The Q in the part number or order acknowledgment for HL6 references the quiet latch. Features and Benefits Quiet functionality Dampened paddle action – depression and snapba...:
Schlage RC-15, RCK-15, and RC-11 - Factory Default Reset (FDR process)
Resolution:
Schlage RC reader-controllers require to be reset to Factory Default for reasons including Getting ready to recommission into Engage after being deleted from a site. As part of troub...:
Will Von Duprin cut and size exit devices prior to shipping?
Resolution:
Von Duprin does not offer custom cut to size exit devices at the factory. Devices must be cut in the field.:
Where is the template for the Schlage L9000 series Gen1 indicator?
Resolution:
For rose (sectional) trim:Door should be prepped in accordance with the correct template for the particular lock function and trim. Pre-drill the 5/8" hole above the center line on the side th...:
Can Schlage Residential Locks Be Used on Screen or Security Doors?
Resolution:
Schlage residential locks are not designed for outdoor use and cannot withstand exposure to the elements. The interior components of these locks must be installed indoors in a temperature-controlle...:
Are Schlage Encode Series Locks Compatible with Alarm.com?
Resolution:
Yes the Schlage Encode Series locks, including models BE489, BE499, and FE789, are compatible with Alarm.com. Where to Find Compatible Schlage LocksFor a comprehensive list of Schlage locks an...:
«
852
853
854
855
856
»