Schlage Control Lock - Long Beep and Green Light on Valid Card Presentation
Resolution:
The lock will display a long beep and green light on a valid card presentation when the unit has lost power long enough to lose it's internal clock time. To correct this, sync the lock with t...:
Schlage M420, M450, M490 - Armature Bolt Replacement
Resolution:
The armature bolt is not available on its own, but it is included in the armature mounting fastener pack, part# P44489128 for M450/M420 P44497110 for M490 :
Schlage SM10 - Not Compatible with OSDP 485 Configuration
Resolution:
The SM10 readers are do not support being ordered as -485 configuration. The unit supports wiegand output only. If -485 OSDP is needed, recommend using MT11 or MT15 instead, or as of late ...:
Schlage AD-series - MT Reader Head Compatibility with HID iClass SEOS Credentials
Resolution:
The MT and MTK reader heads for the AD-series locks will ONLY read the public CSN of iClass cards, which with SEOS means a different random CSN every time the card is read. Recommendation: Use Si ...:
Schlage SM10 - Firmware Compared to MT-series
Resolution:
The firmware on the SM10 is the same as the MT-series readers, except only the X14 firmware package is loaded.:
Schlage CO220 - Ribbon Cable Part Number
Resolution:
The CO220 shares the same ribbon cable as the privacy and office function CO200s. Replacement part number: 23518384:
Installing Electromagnetic Locks on Surface Vertical Rod Doors
Resolution:
It can be installed frame side of the rods, if there is room for it on the door. Note: The holding force will be reduced when the maglock is not installed as close to the edge of the door as ...:
Schlage Control FE410 - Interior Lever Retracting Deadbolt, but not Deadlatch
Resolution:
Check the handing plate on the exterior is seated properly. Incorrect installation of the handing plate can cause the spindle to not engage with the interior hub.:
Schlage MTKB - Keypad Output Configuration
Resolution:
The MTKB readers use the same keypad configuration as the MTK readers. Please see configuration manual here. :
Schlage / Von Duprin RU and RM - Use in Engage Managed Standalone Account or Site
Resolution:
Remote undogging (RU) using ENGAGE software via Wi-Fi is available for scheduled lock-up events only without the need of an ENGAGE Gateway. Note, this solution is not available for real time lock...:
«