Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
759
760
761
762
763
»
Question
Answer
Can the M490DE be installed as a side mount?
Resolution:
No, the DE has never been tested for vertical or side mounting, this is not recommended.:
Can you bench test a GF3000 without using the armature plate?
Resolution:
No, the lock needs to see the magnets aligned, the armature triggers the bond.:
How does the HKII work with power when someone put their hand in the reader?
Resolution:
The HKII works like an "open collector" type it has 4.5 volts then drops to 0 after a scan, that drop will then Trigger the relay.:
What would cause the GF3000 to be hot?
Resolution:
First make sure the control module is installed and the DC power is correct.Confirmed no AC leakage - turn meter to ac should measure 0. some switching power supplies give ac on the dc and th...:
Is the 593PI-12DC 120 VAC to 12 VDC Power Supply UL listed?
Resolution:
It is just a plug in transformer, so it is not UL Listed.:
Can you use the WP-RX switch instead of the RX-LC switch used with the AD or CO exit trim locks?
Resolution:
Yes, since the WP-RX is low current, it can be used instead of the RX-LC switch. :
Does the 23703481 USB Wall Plate With Panel Mount Cable for the CT5000 come with the USB 15 ft cable?
Resolution:
No, the 15ft USB is a separate part number. CT5000 15 ft. USB Cable is 23787088.:
Can a LEMS-ADD be converted to a LEMS-GRW?
Resolution:
No, there are too many parts to try and convert. It is best to reorder a complete new lock. :
What is the Part Number and availability for the Spindle and Spring for CO Locks?
Resolution:
You need to order Door Thickness Kits to get those parts.For CO Cylindrical locks, the PNs are;23599376-138 1-3/8" Door Thickness Kit 23599376-112 1-1/2" Door Thickness Kit 23599376-158 1...:
If the Master Programming Card assigned for Standalone/Construction Access on NDE80 locks is lost, do I need to re-enroll the previously assigned Construction Cards?
Resolution:
If you need to add more Construction Access cards, then you must FDR the lock to create a new Master and re-assign the cards for access. If you are not adding cards, the old ones will still w...:
«
759
760
761
762
763
»