Question
Answer
On the PIB-300, is the REX contact, NO or NC?
Resolution:
It's field selectable. Also, without the RLBD, it's a TTL output that holds 5V against ground, then when it changes state it sinks to ground. If they need a dry contact, they need the...:
Is there a limit on how many gateways can be daisy chained or depends on ACP?
Resolution:
The limit is dependent on what the access control systems can handle. :
How are the secure keys and formats in smart cards handled?
Resolution:
When it comes to secure keys and formats, you can look at it like this: The customer, owns that config, we just have permission to use it. They have to authorize people to use their car...:
How many MT20W's you can have on a site?
Resolution:
There is no limit to the number of MT20W's you can add to a site. You can commission as many MT20W's as you would like. :
Can the M490DE be installed as a side mount?
Resolution:
No, the DE has never been tested for vertical or side mounting, this is not recommended.:
Can you bench test a GF3000 without using the armature plate?
Resolution:
No, the lock needs to see the magnets aligned, the armature triggers the bond.:
How does the HKII work with power when someone put their hand in the reader?
Resolution:
The HKII works like an "open collector" type it has 4.5 volts then drops to 0 after a scan, that drop will then Trigger the relay.:
What would cause the GF3000 to be hot?
Resolution:
First make sure the control module is installed and the DC power is correct.Confirmed no AC leakage - turn meter to ac should measure 0. some switching power supplies give ac on the dc and th...:
Is the 593PI-12DC 120 VAC to 12 VDC Power Supply UL listed?
Resolution:
It is just a plug in transformer, so it is not UL Listed.:
Can you use the WP-RX switch instead of the RX-LC switch used with the AD or CO exit trim locks?
Resolution:
Yes, since the WP-RX is low current, it can be used instead of the RX-LC switch. :
«