Question
Answer
Does the Falcon 510 L NL lever trim turn?
Resolution:
Does the Falcon 510 L NL lever trim turn?No, the 510 L NL trim has a rigid lever. The key entry "lifts" a part inside the exit device which retracts the latches on the Falcon 25 exit device.&...:
Will the Falcon MEL conversion kit work for an existing Falcon EL 24/25 exit device?
Resolution:
Will the Falcon MEL conversion kit work for an existing Falcon EL 24/25 exit device?No, the solenoid at the end of the baseplate cannot be removed on the Falcon EL device. The MEL motor canno...:
Can the Von Duprin E370 control be converted from Fail Safe to Fail Secure in the field?
Resolution:
Can the Von Duprin E370 control be converted from Fail Safe to Fail Secure in the field?No, the E370 is considered "Engineering Special" and must be ordered complete from the factory. :
Is the Von Duprin SS device keyswitch momentary or maintained?
Resolution:
It is a momentary keyswitch. Therefore, a time delay feature is needed in the power supply. And a separate wall keyswitch would be needed to turn the system on and off for extended...:
Since the Von Duprin EL and LX options use an activating rod, how are both options accomplished in the same device?
Resolution:
There is a unique EL-LX switch kit that must be used. The EL and LX share one activating rod.:
How do I order an NL-OP function for a Falcon 24-C or 25-C exit device?
Resolution:
The cylinder control needed for this NL-OP device is a 718C-C. The device would be specified as 24C-C or 25C-C.:
How does Von Duprin package the cables for EL and QEL devices?
Resolution:
Prior to 2019, the QEL/EL cables and EL pulse width module were always bagged and boxed separately inside the exit device box. In fall 2019, the factory began to connect the EL pul...:
For delayed egress products greater than 15 seconds, who grants approval and who needs proof of the approval?
Resolution:
The IBC says, “Where approved, a delay of not more than 30 seconds is permitted on a delayed egress door.” Over 15 second delay requires approval (not necessarily a letter) from the auth...:
Are the PL7 and PL8 BHMA graded?
Resolution:
The PL7 and PL8 are not certified for BHMA grading.:
Are Full Size Interchangeable Construction Cores installed when ordering L9000 series with construction cores?
Resolution:
The construction cores are installed into the mortise housing.:
«