Question
Answer
Does Falcon stamp Facility codes on restricted keys?
Resolution:
In mid year 2019, Falcon began stamping restricted keys with Facility codes. The Facility code will begin with an "F" and would have (5) digits following the "F" similar to Schlage Facility codes.E...:
Is there an SFIC spacer required for use with the ALX series lock?
Resolution:
The ALX series requires (1) D500-000 spacer for 6-pin SFIC cores. No spacer is required for 7-pin SFIC cores.:
Did the 338 Strike change in 2019?
Resolution:
The 338 strike used with several Von Duprin concealed vertical rod exit devices did change. Starting October 15, 2019, the new version of the strike has a roller on the front edge of the strike. ...:
What is the inrush current for the motor-driven Chexit deivce?
Resolution:
The motor driven Chexit operates with 24VDC and requires a 1.25A inrush and 390mA holding current.:
Which GJ overhead replaced the GJ 324
Resolution:
The 410 replaced the 324 but is NOT a direct replacement. Screw holes are different.:
What is the base material for the 10-025 and 10-072 strikes?
Resolution:
605, 606, 609, 619, 622, 625, 626, 626AM and 643e strikes use brass as the base material. 612 and 613 strikes use bronze as the bass material. 629, 630 and 630AM use sta...:
Are Ives 3SP1 spring hinges ADA compliant?
Resolution:
The 3SP1 spring hinge is not published as ADA compliant. Spring hinges apply closing force to the door through their springs which can affect the lbs. of force needed to push a door open.&n...:
What is the L9081 Accessible Storeroom function lock?
Resolution:
As of March 8, 2021 the L/LV9081 Accessible Storeroom Lock will be a standard offering (Previously ordered through Specials as XL13-324). Function- The new L/LV9081 function st...:
What cylinder is used for the Falcon 718 C trim when used with the 24/25 C exit device?
Resolution:
What cylinder is used for the Falcon 718 C trim when used with the 24/25 C exit device?A mortise cylinder must be used, 1 1/4" in length with a straight "skinny" cam (Schlage part number B520-731):
Will the Falcon 1790 EO (exit only) exit device accept a rim cylinder from the pull side of the door?
Resolution:
Will the Falcon 1790 EO (exit only) exit device accept a rim cylinder from the pull side of the door?No, there are parts that must be ordered to accept a cylinder function. To avoid this issu...:
«