Question
Answer
Are the 4631 and 4642 hydraulic cylinders the same?
Resolution:
The 4631 hydraulic cylinder (4631-3971 cylinder only) and the 4642 hydraulic cylinder (4642-3971 cylinder only) are not the same as the internal components are assembled differently. So they ...:
Is the electrified L9000 PCB still available?
Resolution:
The electrified L9000 PCB (L283-344) is no longer available and there is no replacement. Complete lock chassis must be ordered.:
What is the minimum height of a 377T used with an 8827 or 8827-F device?
Resolution:
With the 8827 or 8827-F device mounted at the standard centerline of 39 13/16" above the finished floor, the centerline of the thumbturn can be located at 46 1/2” above the finished floor minimum.:
Can the Schlage D-series be converted from conventional cylinder to full size interchangeable core?
Resolution:
Using kit 04-030, you can convert the Schlage D-series from a conventional cylinder prep (PD) to a full size interchangeable core prep (JD). Using kit 04-034, you can convert the S...:
What size security bit would be used with the X Mount option?
Resolution:
The X Mount security mounting option for Ives pulls is a "pin in star" design that is 5/16" diameter with an 1/8" pin in the middle.:
What mortise cam operates the Emtek 3300 series mortise lock from Assa Abloy?
Resolution:
The Emtek mortise entrance locks (3300 series) use the A92 mortise cam. Schlage does not offer an equivalent mortise cam.:
Does the ND series fall under the UL305 testing?
Resolution:
The ND series cylindrical are not tested to the UL305 as this applies to Panic Hardware.:
Can the 4040(XP)-384 stop be used in a 4050A Cush arm?
Resolution:
Yes.:
What material are the ND levers made of?
Resolution:
ND lock levers are made of pressure cast zinc. :
Does the Von Duprin Chexit 98/9927 Surface Vertical Rod exit device require rod guards?
Resolution:
Does the Von Duprin Chexit 98/9927 Surface Vertical Rod exit device require rod guards? Yes, this device requires rod guards as pulling down and lifting up on the surface vertical rods can by...:
«