Can I mount the Glynn Johnson 103 on a 40" door?
Resolution:
Can I mount the Glynn Johnson 103 on a 40" door? Yes, the overhead can be mounted on larger doors, not always on smaller doors. You must calculate the "A" dimension then add the "...:
Can I use the Von Duprin 5100 electric strike for mortise locks?
Resolution:
Can I use the Von Duprin 5100 electric strike for mortise locks? No, the 5100 electric strike is NOT intended for mortise locks, only cylindrical locks (like the Schlage ND 80). &n...:
Can the Von Duprin concealed cable device be converted to a device that uses concealed vertical rods?
Resolution:
Can the Von Duprin 33/35/98/9949 device be converted to a device that uses concealed vertical rods (33/35/98/9947)? Yes, as long as the device is NOT fire rated, the following parts can...:
Can Dummy Trim be used with Fire Rated Exit Devices?
Resolution:
Dummy Trim can be used with Fire Rated Exit Devices.Because Dummy Trims have no way of unlatching the Exit Device, they are not commonly used with Fire Rated Exit Devices unless the device has Elec...:
Does Von Duprin carry an electric strike for pairs of doors with the typical ANSI 4 7/8" edge prep?
Resolution:
Does Von Duprin carry an electric strike for pairs of doors with the typical ANSI 4 7/8" edge prep? NO, Von Duprin does NOT carry an electric strike for pairs of doors with a 4 7/8" edg...:
Is the Falcon X lock discontinued?
Resolution:
The Falcon X lock was discontinued in July 2024 and is no longer available. :
Is the LT172 double dummy trim just a pair of LT170 single dummy trim?
Resolution:
The LT172 double dummy trim sets do not have any unique components; two sets of the LT170 single dummy trim sets are provided.:
Are Schlage or Falcon electrified locks listed to UL1034?
Resolution:
Schlage and Falcon electrified cylindrical and mortise locks are not listed to UL1034.:
Von Duprin and Falcon Technical Support Videos
Resolution:
Allegion product support agents continually add to the library of common support questions. Click HERE for the Allegion Commercial Product Support YouTube channel. These ...:
What is the L283-057 OSU ferrule pack used for?
Resolution:
Used on lower quality doors with a particle core that effectively oil can during the installation. These were designed for those doors and not for general use to prevent oil canning on meta...:
«