Question
Answer
Did the dimensions on the mounting posts on a 20 year old 22 series device change from what we offer today?
Resolution:
No. The mounting posts of a 22 have never changed. :
Will the RX switch from a Von Duprin 99 series work with a Falcon 25 series?
Resolution:
The RX switches from Von Duprin (050251) will not work with Falcon exit devices(650359) and vise versa. :
Can the 237L be ordered for a 10' tall door?
Resolution:
This can only be done as an engineering specials.See the front of the Von Duprin price book for information on engineering specials.:
Are the 996L escutcheons sold seperately?
Resolution:
No, they have to be ordered with a complete trim. :
Is the bolt on the Ives FB41T and or FB41B adjustable? If so, how is this accomplished?
Resolution:
The bolt can be adjusted up to 7/8" by turning the threaded bolt housing into the body. It can be adjusted so that the bolt is flush with the top of the door when in the retracted state. ...:
Does Falcon offer a pullman or ES top latch for the Dor-a-matic 1490?
Resolution:
The SU latch for the 1490 and the 1690 are the same. :
Can the electrified ND lock be used in an outside application?
Resolution:
Not recommended for outdoor installations.:
Will a Schlage FSIC fit into a KS series padlock with conventional cylinder prep?
Resolution:
While the KNK prep does have a figure 8 pattern (a shroud surrounds the bible of the cylinder), it is not compatible with Schlage full size interchangeable core. :
What is the tallest door the L9000 can be installed to maintain the UL listed 3 hour fire rating?
Resolution:
Schlage L9000, L9400 is approved for use on single doors rated up to three hours with a maximum size of 4’-0” x 10”-0”.:
What is the tallest door the MA lock can be installed to maintain the UL listed 3 hour fire rating?
Resolution:
MA series is approved for use on single doors rated up to 3 hours with a maximum size of 4'0" x 8'0". :
«