What power supply is required for the QEL device?
Resolution:
For a simple application with a card reader and 1or 2 QEL devices, a PS902 x 900-2RS is required. The QEL device has a 1 amp inrush of 24VDC to retract the exit device latch, an...:
For the M490 angle brackets, what size tap would be used for the metal screws?
Resolution:
Metal screws for the angle bracket is #12-24:
Does the DPS get shipped with CO-200-MD?
Resolution:
The MD does not use the DPS since there is a switch built in to the thumb turn of the deadbolt. Only push button 40 and 60 include the DPS on the CO-200.:
Can you tie the 679-05 DPS to 2 different ACP to monitor the door?
Resolution:
No. The ACP will use the contact of the DPS to send a voltage or signal through to know if the switch is open or closed. So without knowing if the two panels use the same voltage or signal, it woul...:
Can you run 24volts thru the NO and C of the 900-FA board?
Resolution:
Yes, 24VDC is fine, since the relay on the FA board is rated for 30VDC 1A max.:
Is the tailpiece for the CO and AD cylinders different from the NDE lock cylinders?
Resolution:
The AD and CO locks do NOT have the same tailpieces as the NDE locks. They are different lengths. :
Where can you punch the ISO cards
Resolution:
Please see attached.:
What terminals in back of HKII reader is need to be shorted to stop the message, "Door open too long"?
Resolution:
Pins 10 and 11:
What does LGR indicate for PS902 2RS LGR?
Resolution:
LGR refers to the finish of the power supply, light grey.:
What is the dimensions of the CT5000 USB wall plate?
Resolution:
The dimensions are 4 1/2 X 2 3/4 X 5/16 inches.:
«