How does the indicator trim operate on the ND44 Hospital Privacy lock?
Resolution:
Engaging the push button will lock the outside lever and activate the outside indicator trim to read either Occupied or Locked.Rotating the inside lever retracts the latch, releases the button unlo...:
How does the indicator trim operate on the ND50 Entrance / Office lock?
Resolution:
Engaging the push button will lock the outside lever and activate the indicator trim to read either Occupied or Locked. This will apply to both inside and outside indication trims. Key outside...:
How does the indicator trim operate on the ND52 Keyed Privacy Lock with Automatic Unlocking?
Resolution:
Engaging the push button will lock the outside lever and activate the outside indicator trim to read either Occupied or Locked.Key outside, or rotating the inside lever retracts the latch, releases...:
How does the indicator trim operate on the ND53 Entrance lock?
Resolution:
Engaging the push button or pushing and turning the button will lock the outside lever and activate the indicator trim to read either Occupied or Locked. This will apply to both inside and outside ...:
Is the L9453 handing procedure different than a standard L9000 series Lock body?
Resolution:
A redesign of catch spring makes it necessary to add a step when handing the L9453.You must first throw the deadbolt when moving the lock handing screw.A notice will be provided in the box with the...:
What are the plastic buttons on the MA strike for?
Resolution:
The MA strike has nylon buttons inside the strike hole to reduce friction and help the latch when there is a warp door load. :
When was the 2211 and 2211DPS discontinued?
Resolution:
The LCN 2211 and 2211DPS, Size one only closer, was obsoleted on 10-30-2009.:
Are there any additional size thru bolts available for Falcon closers, for doors other than 1 3/4" thick?
Resolution:
Falcon SC Series closers (SC70A, SC80A, SC60A) only come with Thur bolts for a 1 ¾" thick door.Potential solution: LCN does offer TB's for 1 3/8" or 1 5/8" doors and these TB's could be used ...:
What voltage does the L9000 MLR require?
Resolution:
The L9000 MLR functions require 24 VDC power to operate. You cannot use 12VDC or AC voltage. :
How long does it take for the latch to retract on the L9000 MLR?
Resolution:
The L9000 MLR uses a stepper motor to retract the latch with less than ½ second activation once power is applied.:
«