Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
1170
1171
1172
1173
1174
»
Question
Answer
What are the plastic buttons on the MA strike for?
Resolution:
The MA strike has nylon buttons inside the strike hole to reduce friction and help the latch when there is a warp door load. :
When was the 2211 and 2211DPS discontinued?
Resolution:
The LCN 2211 and 2211DPS, Size one only closer, was obsoleted on 10-30-2009.:
Are there any additional size thru bolts available for Falcon closers, for doors other than 1 3/4" thick?
Resolution:
Falcon SC Series closers (SC70A, SC80A, SC60A) only come with Thur bolts for a 1 ¾" thick door.Potential solution: LCN does offer TB's for 1 3/8" or 1 5/8" doors and these TB's could be used ...:
What voltage does the L9000 MLR require?
Resolution:
The L9000 MLR functions require 24 VDC power to operate. You cannot use 12VDC or AC voltage. :
How long does it take for the latch to retract on the L9000 MLR?
Resolution:
The L9000 MLR uses a stepper motor to retract the latch with less than ½ second activation once power is applied.:
Do you need to install the Alignment cylinder on the Gen 2 indicators?
Resolution:
The Alignment cylinder is required to be installed so the spindle is not taking the weight of the indicator by aligning up the indicator with the spindle. Binding will be apparent if the alig...:
What is the peak amperage for the L9000 MLR?
Resolution:
L9000 MLR - Max current 1.4 ampsL9000 MLR w/ lever control - Max current 0.4 amps:
Why does the Falcon W581 storeroom function chassis have a push button?
Resolution:
The Falcon W581 Storeroom lock utilizes the same chassis as the Falcon W501, W511, and W571. When the W581 lock ships, it has a visible button on the inside chassis spindle. The way sto...:
Are RX and RX-2 options available for Von Duprin 2-foot devices?
Resolution:
Electrical options that occupy the space between the end cap and the push pad of the device are not allowed on the 2' sized 98/99 or 33A/35A Surface or Concealed Vertical Exit Devices.The RX, RX-2,...:
Can the Falcon MA mortise lock be used on a door with Government 86 prep?
Resolution:
Government 86 door prep (oval cut-out) does not accommodate the Falcon MA mortise lock with either rose or escutcheon trim. :
«