Question
Answer
The 4630/4640 operator can accept any ( normally open / dry contact) actuator - hardwired or wireless.  LCN Wireless actuators require the use of the 8310-865 RF receiver.The 8310-856 RF ...
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature. &nbs...
The 4630/4630 operator has a 12 VDC and 24 VDC output that can power an electric strike or maglock. The wiring diagrams are shown on page 14 of the installation instructions (attached). 4600 Insta...
The Senior Swing 9500 or 2800 series operator is designed to for "High Traffic - High Abuse" areas.
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. This harness p...
Electro-hydraulic Automatic Operators are: Designed for manual opening applications where there is occasional need for automating the door to meet ADA requirements.  Electrically powere...
The 8310-877 comes with a 6 wire cable. You have to cut the connectors off both ends and hardwire it to the 4600 operator as follows: The 6 wire cable connections to the 7 pin connector in the 8310...
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...
 EL devices are wired to the Senior Swing, using the P10 (761465) cable.  Connect the "GRAY" wire to the SC terminal on the 900-2RS card in the Von Duprin Power Supply and the "VIOLET" wire to the ...
The 8310-865 RF receiver contacts (N.O. and COM) would connect to terminals 15 & 17 (the alternate action input) on the 4600 operator. The first activation would open the door, the second...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...
The 8310-865 RF receiver connection to the Falcon 8200 operator are: RED and BLACK power wires on the receiver connect to the 12V AC terminals on the Falcon operator. The WHITE wire from the COM t...
See Point to Point wiring diagram here.
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.