senior Swing controller flashing light

RELATED FAQS

Question
Answer
There is a total of 4 red buttons on the front of the Senior Swing control box. To turn on the display, press and hold any 2 of the 4 red buttons at the same time for approximately 3-5 seconds. Y...
The Senior Swing control box is ordered as a 95xx-3462. Example - 9530-3462, 9540-3462.
The Senior Swing Series changed to the "Digital" control box in Sept. of 2006.
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box with...
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. This harness p...
The Senior Swing "control box" is not handed. All Senior Swing motor "gearboxes" are handed, both the 2800 Series concealed and 9500 Series surface mounted operators. The 2800 Series "concealed a...
Verify that the 120VAC is present at the controller (measure 120VAC on the 2 wire gray cable from I/O board to controller -- red/black wires in gray cable). If present, but no lights on the contr...
A red and green flashing LED's on a QEL indicates the device has been tampered with while power was applied, the push pad was pulled out at least three time. Wait 15 seconds and latchbolt will retr...
The push bar being pulled out three times while power is applied causes the lights to flash and the device to stop retracting.
Check to make sure there is no bind of the latch.