Question
Answer
What actuators can be used on the 8310-866 Bollard post?
Resolution:
The LCN Bollard post (8310-866) only accepts the "square" actuators (no round actuators). The size of the Bollard post is 4” X 6” X 36”. Acceptable actuator part numbers are: Hard Wired - 831...:
Will the 8310-853 actuator mount in a single gang or a double gang box?
Resolution:
The 8310-853 (T) series actuator will mount to either a single or double gang electrical box.:
Can a 8310-818 be used outside?
Resolution:
Exterior mounting of the 8310-818 series actuators is not recommended. The 8310-818 series actuators are designed to be jamb mounted on the frame. With that installation, the person will have to ...:
What is the Buy American Act (BAA)?
Resolution:
BAA/ARRA stand for Buy American Act and American Recovery and Reinvestment Act. A brief description of some of the federal requirements can be found in the BAA Catalog on the Allegio...:
What are the ANSI recommendations for the actuator mounting height and distance between the wall actuator and the door opening?
Resolution:
Always check the most current revision of the ANSI A156.19 standard for recommendation or requirement of the location of a Knowing Act switch. 2019 ANSI A156.19 states the requirement of the ...:
Which terminals on the 4630/4640 operator are used for activation?
Resolution:
The 4630/4640 operator activation inputs are: Normal Activation Inputs (2 parallel) - terminals 16 & 17 or 18 & 19. Sequential Input - terminals 8 & 19. Alternate Action Input - terminals 15 &...:
What could cause a 9100 Series Benchmark operator not to open when the actuator is pushed?
Resolution:
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...:
What wires are the activation inputs for the Senior Swing?
Resolution:
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. ...: