Question
Answer
Steelcraft doors and/or frames do not contain any asbestos. Steelcraft did use asbestos in the following products: Steelcraft S16-Series stile and rail door with flush panel and UL fire door l...
Steelcraft does not offer factory powder coated doors and/or frames. Powder coatings usually require heat between 300 to 400 degrees to melt and cure the powder coat. The higher heat can ca...
No. The Steelcraft H-Series hurricane door does not meet the FEMA 361 guidelines. The Paladin (PW14-Series) door does meet the FEMA 361 guidelines.
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
FastTrack is a quick ship stock program which includes targeted Builders Hardware SKUs offered by Allegion Distributor Partners. FastTrack order forms and supporting information is available only t...
Allegion Employees can access the distributors’ “My Allegion Portal” thru The Frontline Home Page: Click on “My Allegion Distributor Portal” located in the navigation menu on the left si...
Tornado shelter applications require the use of Paladin PW14-Series doors and FP14-Series frames: Tornado shelter doors are a tested system comprising of the door, frame and hardware. ...
Levels and Models (covered in ANSI A250.8 (SDI 100) "Recommended Specifications for Standard Steel Doors and Frames") are SDI term aid in the selection and specification pr...
Yes, wood doors can be used and installed in most hollow metal frame applications including FE-Series and DE-Series Double Egress frames. Caution - For fire rated applications the wood door manufa...
No actual templates exist for this hardware. This hardware is currently only available for use on the Steelcraft Paladin series door and frame assembly and is sold as a complete package with the lo...
Steelcraft frames and doors are furnished with a high grade, low gloss, baked-on prime paint that provides the best possible protection against corrosion, abrasion and weather, and is an excellent ...
FBC Approvals: Yes, Steelcraft doors do meet the Florida Building Code (FBC) Protocols (TAS 201, TAS 202 & TAS 203) Missile impact & ASTM E-330 applications Dade County NOAs: Yes,...
Hinge Spacing: All 4 1/2" and 5" butt hinge spacing 1. Opening heights 3'0" through 4'11 15/16" (one pair butt hinges) from under head CL 9 3/4" (top of door 9 5/8") from bottom of frame ...
Hinge Backset: On the frame = 5/16" On the door = 1/4"
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening ...
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...
Steelcraft offer a limited warranty to customers that products will be free from defects in the material and workmanship for a period of 12 months from date of shipment of products.Warranty St...
Job Specific Warranty - If job specific warranty letters or certificates are required, please refer to the Allegion Contact Us web page and request the applicable information.NOTES:F...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...
For both DW and K-Series Drywall Slip-on frames, Steelcraft locates the compression anchor in the jamb soffits approximately 4" down from the head on each jamb. Regardless of door opening height: ...
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame.
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
Yes, Steelcraft does offer optional A60 and A40 Galvannealed, and G90 Galvanized steel on doors and frames. Galvannealed A60 and A40: A60 coating designation - optional on all doors and frame...
All Steelcraft Frame, Door and Architectural Stick components will receive one coat of sprayed-on factory paint which is a baked-on, rust-inhibited primer that conforms to the industry standard ANS...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documentsClick here to get the updated link to the Steelcraft Shop M...
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...
Yes, stainless steel doors and frames are available. Door Construction: LS-Series: Visible edge seams Door construction similar to the ...
Factory finished painted doors are available from Steelcraft. Frames "are not available" factory finished from the factory. Doors are offered in variety of standard colors or can be fini...
Side Light and Side Panel frames - Side Light and Side Panel frames are not KD (Knock Down), they must be assembled and welded. All side lite and side panel frames must be assembled and welde...
ASTM E-119 is a test standard for walls, partitions and floor or roof systems: This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames. ...
Steelcraft follows the industry standards for hinge reinforcement and preparation for both door and frame. Unless otherwise specified all products prepared for butt hinges will have mounting holes ...