Level five doors

RELATED FAQS

Question
Answer
The minimum top and bottom butt hinge locations are as follows: To the hinge centerline: 4 1/2" and 5" hinges = 5 3/8" is the minimum location from top of door to centerline of the first hi...
Steelcraft follows the industry standards for hinge reinforcement and preparation for both door and frame. Unless otherwise specified all products prepared for butt hinges will have mounting holes ...
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device.  Maximum allowed force to retract the Von D...
The CS210 has a patented center-to-center adjustment that will switch from the standard 4" door prep to 5-1/2".  Only these two dimensions are available.
Some Access Control Panels are designed with “Supervised” or “Dry contact” requirements for the inputs and have no common ground between the ACP (Access Control Panel) and device at the door. “S...
Schlage offers the “RLBD” to support these supervised or dry contact interface applications. The "RLBD" plugs directly into the PIM400-TD2 or PIB300-TD2 for easy hook-up.  
Please reference this Tehnical Note RLBD SES-20120418 for RLBD setup, use information, hook-up diagrams and some testing suggestions when connecting to a Supervised dry contact Access Contro...
This is a link to the RLBD Installation Instructions.
This RLBD data sheet can also be found at Schlage/Technical Support. RLBD DataSheet
At this time, Allegion does not supply products with bullet resistant ratings.   Bullet resistant (BR) doors are designed to protect people and property from firearms’ bullets and shrapnel. ...
Levels and Models (covered in ANSI A250.8 (SDI 100) "Recommended Specifications for Standard Steel Doors and Frames") are SDI term aid in the selection and specification pr...
The SUS can change the logic polarity of the AD400/WRI400 PIM400-TD2 outputs RTX, DPS, TROUBLE, and REN from LOCK/DOOR PROPERTIES Edit tab. You can change High to Low to High using the ed...
  These SUS settings have no effect when the AD400 is linked to a PIM400-485; because the PIM400-485 reports the logic status with RSI-485 commands and not logic levels. The settings are gray...
Blast and pressure resistant doors protect people and property from explosions and shrapnel. More damage is generally caused by shrapnel than the blast itself, and a properly specified and engineer...
Steelcraft Blast Resistant Assemblies meet the following Blast Test Standards:                    ...
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the sa...
The maximum width door the Steelcraft can make is 4' 0"