The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application. Check the template to confirm compatibility with specific cylindrical lock model n...
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.***
Note: The Best 40H series lock is not listed on the 6210 electric s...
The 9550 series Senior Swing WILL NOT work on a pair of doors with auto flush bolts.
The 9560 series Senior Swing and a sequence module are required when used on an pair of door with auto flush b...
The door handing determines the finish of the latch and strike.
Left reverse and right reverse doors default to outside trim
Left and right hand doors default to inside trim
If lever an...
THIS ITEM IS DISCONTINUED - See the related solution "Is a latch bolt monitor available with the Schlage mortise electrified locks?"
Latch monitoring, or LM is available as an op...
None of the Von Duprin electric strikes will work in a retrofit application where the normal standard mechanical strike is mounted to the frame because none of them are thin enough to fit in...
You can't run 24VDC into the 12VDC electric strike, over voltage such as this will cause the solenoid to heat up and damage the solenoid. You must change to a 24V solenoid, part number 050240-00.
The Falcon 25R rim device can be used with 6111 electric strike on single or double doors.
Additional Information:
The Von Duprin 4854/9854 mullion is required when using 25R...
For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door.
For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable.
To power the 24VDC electric strike or maglo...
The DS is Dual Monitor Switch for Von Duprin 6000 series electric strikes.
DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only available factory inst...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes.
Electric Hinges:
Most electric hinges will fit into...