full glass door ept

RELATED FAQS

Question
Answer
Levels and Models (covered in ANSI A250.8 (SDI 100) "Recommended Specifications for Standard Steel Doors and Frames") are SDI term aid in the selection and specification pr...
Glass lights are available in fire rated T-Series doors: Limited to one (1) light per door leaf with a maximum of 100 square inches of exposed glass. This applies to all hourly ratings a...
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design. A14-Series door construction: Max fire rating is 20 minute. UL label only FG must use Over-Lapping Stee...
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, glass light designs and hardw...
Glass Light is a preparation in a door for view window, vision and/or glazing including glass stop and glazing bead and may also be refereed to as a lite. Doors are available with a wide variety o...
Maximum nominal (overall) single door sizes are as follows: L-Series (Laminated Door) 20 Gage = 3’ 0” wide X  8’ 0” high 18 Gage = 4’ 0” wide X 10’ 0” high 16 Gage = 4’ 0” wide X 10...
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...
You can only use one GBK Glass Bead Kit (1/4") per device on fire rated openings. Glass Bead Kit is for use on doors with raised glass beads.
When dealing with glass lights in doors, there are three (3) critical dimensions which must be coordinated: Exposed Glass Size (EGS) - the horizontal and/or vertical dimensional size of the vision...
The Schlage L-Series mortise lock spindle and spring part number can be found in the Table 1.     Spindles and Springs   Part Number  Description  L283-060 Spindle and spring, 1...
A fire rated door for 3 hours can have one glass light maximum: 100 square inches and must have an approved glass (Firelite type) Max glass size cannot exceed 12" in width or 33" in height. Wi...
The minimum stile and rail dimensions with glass trim are as follow: Top Rail: 6 1/4" top of door to exposed glass or 5 1/2" top of door to cutout Center Rail: 6 1/2" exposed gla...
The wires run through the device out to the EPT. See step 7 on page 5 of E996L instructions.
Minimum dimensions to cutouts for glass lights: Vertical edge of door to edge of cutout = 5 29/32" Top of door to top of cutout = 6" Bottom of door to bottom of cutout = 10" Reinforcing chann...
Window kits are available for Steelcraft doors as either factory installed or prepared and installed by a distributor. Factory prepared light cutouts are supplied with Dezigner trim as st...
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin recommended template locati...
The GCS (Glass Cutting Size) is determined by adding 1 1/4" to EGS (Exposed Glass Size) to both the height and width dimensions. Ex: EGS = 20" w. x 30" h. GCS = 21 1/4" wide x 31 1/4" high St...
EPT power transfer preparations are not available on the Paladin PW14-Series door and FP14-Series frame. Electrified hinges are available on the Paladin PW14-Series door a...
Dezigner Trim – This unique and patented glass trim has been designed to closely simulate trims installed in wood doors and is factory: Supplied recessed into the door face, to provide a neat f...
Flush Mounted Steel Trim for Insulated glass – Designed for 1” thick insulated glass. Recessed into the surface of the door face Accommodates 1" (25 mm) thick glass. When installed, fastener...
Overlapping Steel Trim (also refer to as conventional steel trim) – This trim is the typical glass trim supplied by most hollow metal manufacturers. Surface mounted on the door face. Accommo...
Flush Mounted Steel Trim – This trim is similar to Overlapping Steel Trim but is factory supplied recessed into the door face and is available for 1/4” glass. Glazing stops are screw attached, fast...
 Basic glass trim details:
Yes. Multiple glass lights are available on specific door series as  a special option as noted below: L-Series and SL-Series: Core options - Standard honeycomb, polystyrene, polyurethane Lig...
Maximum glass light size for a 90 minute (1 1/2 hour) door depends on the type of glass being installed. Wire glass = 100 square inches is max exposed glass when wire glass is used. Note - ma...
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....
Maximum UL Fire Rated door sizes are as follows: A-Series: 4' 0" X 8' 0" single door 8' 0" X 8' 0” double door or pairs B-Series 4' 0" X 10' 0" single door 8' 0" X 10' 0” double doo...
Aluminum trim is not available. All of our current trim offerings are steel.
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
Doors are available with cutouts only. This practice is used for field installation of aftermarket (non-Steelcraft) glass trim by either the distributor or end user. The following information must ...
Insulated Core Options: Steelcraft L-Series doors are available with the following 2 optional insulated cores: Polystyrene slab - this core is available in non fire rated and fire rated doors...
Maximum glass light sizes for 3 hour fire doors is as follows: Wire glass - not approved for use in 3 hour fire doors. Ceramic glass: UL & ITS/WH allow one (1) light with 100 square inc...
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks a...
Dutch doors are available as Fire Rated door assemblies and have similar component requirements as a single leaf fire door. Exceptions are as follows: The Dutch Door assembly must have a lock...
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...
Surface Mounted door closers are the most durable and common type of door closer. Mounted to the surface of the door or frame Can be configured (through installation or arm type) to meet a...
Falcon SZ Series Door is the economy Steelcraft commercial grade door recommended light commercial applications when architectural specification are not needed. Options: The SZ-Series door is...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documents. SDI (Steel Door Institute) installation manual can be found...
Blast and pressure resistant doors protect people and property from explosions and shrapnel. More damage is generally caused by shrapnel than the blast itself, and a properly specified and engineer...
Steelcraft Blast Resistant Assemblies meet the following Blast Test Standards:                    ...
Steelcraft offers all the standard lights as well as special size glass lights in the H-series door. Effective April 1, 2012, (Bulletin # B-100.12) the default for Dezigner Trim in H-Series Doors...
Yes, stainless steel doors and frames are available. Door Construction: LS-Series: Visible edge seams Door construction similar to the L-Series LSW-Series: Seamless with we...
Yes, glass light can be used or prepped in conjunction with the Von Duprin 94/95 Series INPACT device however there are dimensional limitations between the glass light and the InPact door preparati...
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...
The minimum stile and rail dimensions are to exposed glass are: Stiles = 6 13/16" Top Rails = 6 3/4" Center Rails = 7 1/2" Bottom Rail = 10 3/4" For high traffic and high abuse locations th...