Question
Answer
Can an additional jamb anchor be used as a base anchor on fire rated frames?
Resolution:
Yes, an additional jamb anchor can be used at the bottom of the frame in lieu of the typical (adjustable or weld-in) base anchor in fire rated frames. This is limited to the anchor designed for...:
Are masonry T anchor fire rated?
Resolution:
Masonry T anchor are approved for fire rated frames up to 3 hours. T Anchors are shipped lose for field installation. Anchor construction: The T portion and the strap do have minimum dim...:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
Are adjustable base anchors provided with frames that are prepped for existing opening anchors?
Resolution:
No, an adjustable base anchor is not supplied on frames with existing opening anchors. The anchor design for use in existing masonry walls, is a pierce and dimple in the frame soffit for 3/8"...:
EXISTING WALL ANCHOR
Resolution:
EMA, Anchors, Existing Opening Anchors:
Are stainless steel doors and frames available?
Resolution:
Yes, stainless steel doors and frames are available. Door Construction: LS-Series: Visible edge seams Door construction similar to the ...:
What is the difference between the DW-Series and K-Series frames?
Resolution:
Both the DW and K-Series frames are identical with the exception of the base anchoring. Both the DW and K-series frames are supplied with a field adjustable compression anchor in each jamb locate...:
Can Drywall Slip-on frames be welded?
Resolution:
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installa...:
How many compression anchors are provide per jamb on DW-Series frames?
Resolution:
For compression anchor details refer to the “ANCHORING SYSTEMS” section in the Steelcraft Tech Data Manual.Anchor Quantities: • 1 compression anchor per jamb through 9"depth • ...:
SILL ANCHOR
Resolution:
Anchor:
MULLION ANCHOR
Resolution:
Anchor:
MASONRY ANCHOR
Resolution:
Anchor, Wire Anchor, T-Anchor, Strap and Yolk, Strap and Stirrup, tube and plate, hat, butterfly, completed opening anchor:
COMPRESSION ANCHOR
Resolution:
DW-Series, K-Series, Anchor ; Tension Anchor:
Are frames available without backbends?
Resolution:
F-Series frames are available without returns: Fire Rated frames must have welded corners. Frames must include weled in wood or steel stud anchors. Installation requirements: ...:
How do I cut a door to accept a Falcon W series lock?
Resolution:
For W lock levers, you can choose whether or not to install the mounting posts. This will also affect how the door is prepped so be sure to determine how you will install the locks befor...:
Door hitting the strike jamb?
Resolution:
If the door hits the frame (or rubs on the rabbet of the head or jamb) the frame is out of square and improperly installed. Door edge rubbing on the rabbet - shimming the hinges may resolve the...:
How many anchors are in a frame?
Resolution:
For Steelcraft frame anchor locations refer to the frame "Anchoring Systems" section of Steelcraft's Tech Data Manual. Basic guidelines are as follows: Anchor ...:
What are security jamb anchors?
Resolution:
Security anchors are used in DW/K frames located directly above or below strike preparation on door side of frame. Because there are only two points of anchoring, the compression anchor near the ...:
What anchors are used in FEMA Tornado Resistant openings?
Resolution:
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...:
STEEL STUD ANCHOR
Resolution:
Anchor:
FIXED FLOOR ANCHOR
Resolution:
Base Anchor, Base Clip, or Base Runner, sill Anchor; Welded Base Anchor:
ROUGH BUCK FRAME ANCHOR
Resolution:
Cabinet Jamb:
WOOD STUD ANCHOR
Resolution:
Anchor:
ADJUSTABLE BASE ANCHOR
Resolution:
Anchor, Adjustable Floor Anchor:
ANCHOR
Resolution:
Wood Stud Anchor, Steel Stud Anchor, Universal Anchor, Masonry Anchor, EMA Anchor, T-Anchor, Wire Anchor, Compression Anchor, Mullion Anchor, Sill Anchor, Base Anchor, Adjustable Base Anchor, Adjus...:
CEILING STRUT
Resolution:
Strut, Anchor:
Can DE-Series frames be prepared for pocket pivot hinges?
Resolution:
Pocket pivot hinges are mainly used in cross corridor applications where clear opening width is a factor. For frames, pocket pivot hinges are a special hinge options which must be spe...:
What is the difference between the FE and DE-Series frames
Resolution:
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...:
Does Steelcraft have frame installation instructions?
Resolution:
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documentsClick here to get the updated link to the Steelcraft Shop M...:
What is the rough opening in walls for frame installations?
Resolution:
For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...:
FLOOR STILT
Resolution:
Anchor:
Is the Von Duprin 6223 fire rated for pairs of wood doors?
Resolution:
The 6223-FSE electric strike is fire rated for pairs of wood doors, but check with wood door manufacturer to see if they have been approved for this application.:
Can 5100 electric strikebe used on fire rated door?
Resolution:
The Von Duprin 5100 electric strike is not for fire rated applications.:
Can the 9949 CVC be used on fire rated wood doors?
Resolution:
There are several door manufacturers that have achieved a 90 minute UL Fire listing as shown. Von Duprin CVC with Marshfield Wood Door: Von Duprin is pleased to announce that Marshfield ...: