Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
Are Pneumatic operators available with hold open
”
RELATED FAQS
Question
Answer
What degrees of opening can a 4110 EDA be templated for?
Resolution:
The 4110 EDA/HEDA can be templated for 100°, 140°, and 180° hold open. The hold open adjustment can be set to hold the door at any position (degree) up to the maximum door opening angle. For "Wi...:
How do you wire up the new hold open switch on the 4600 units?
Resolution:
The 4600 Series I/O PC Board was updated in Nov. of 2010. As part of that update, the hold open switch plug in connector was removed, requiring the hold open switch to be field wired on t...:
How to adjust a 4010 hold open arm?
Resolution:
The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...:
How do you order a 4110 hold open spring cush arm only?
Resolution:
The 4110 hold open spring Cush (Spring H Cush) arm part number is 4110-3049SCNS.:
What would cause an ME Series closer (2310ME/4310ME/4410ME) to pop back into hold open as it is closing?
Resolution:
This condition can be caused by the "closing speed adjustment" being regulated for a fast closing speed. Try adjusting the closing speed to slow down the closing of the door. If that does not corre...:
What is the part # for the 4040 regular arm?
Resolution:
The 4040 regular and hold open arms are different. You would have to get a different arm to convert from regular arm to a hold open function. 4040-3077 for a regular arm. 4040-3077L for a long ...:
Where does the hold open switch on the 4630 / 4640 wire into on the 1-24 single terminal strip?
Resolution:
The 4600 hold open switch (for the new 1-24 single terminal strip I/O board) wires into terminals 2 and 6 or 4 and 6.:
What causes a Senior Swing door to hang open and not close?
Resolution:
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...:
Why does the auto operator not open the door when installed with a Chexit?
Resolution:
Chexits are NOT electric latch retraction devices, therefore the latch will not retract and allow the opener to swing the door open. Chexits block and unblock the latch. In order for a Ch...:
What would cause a 4600 operator to click a few times when the actuator is pushed, but not open the door?
Resolution:
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...:
Why would a Falcon 8200 operator have an inconsistent opening?
Resolution:
An inconsistent opening is normally caused by the arm not being installed correctly. The arm must be installed while the operator gearbox is in the full open position, and the door at 90° open posi...:
What would cause a Senior Swing to open only 10 degrees and then close?
Resolution:
Issue/Symptom – upon receiving an activation input the Sr Swing gearbox opens only about 10 degrees and then returns to the close position. Unit will never learn opening nor function pro...:
What are Hold Open Closers & Magnets?
Resolution:
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...:
Will a 4040SE open and hold at 180°?
Resolution:
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position. The 3130SE has an adjustable hold open position from 85° to 110° maximum. ...:
Can a 4600 operator be mounted with pivots?
Resolution:
On a single door take the mounting dimensions from centerline of pivots. On a pair of doors, depending on the door width and pivots being used, the operators can butt up against each other or ov...:
How do I set the hold open on my 4040 closer?
Resolution:
The hold open position on a "REG" or "EDA" hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...:
What is the opening force of a 4600 Series (4630/4640) operator when used manually?
Resolution:
The manual opening force on a 4630/4640 will be approximately 8.5 lbs to 14 lbs depending on the spring setting.:
Will a 4640 operator open the door in windy conditions?
Resolution:
The 4600 operator is designed to meet the ANSI Code 156.19 that limits the opening force to a 15 lbs. By code and design, the operator must stop opening the door when an obstruction or resistance ...:
What would cause a Senior Swing to open too far?
Resolution:
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...:
What would cause a 4600 Series operator to open up and intermittently stick open?
Resolution:
If manually it opens and closes fine, check to make sure one of the actuators is not getting stuck in the on position. Verify that the "Operating Indicator" LED's -- "POWER and SAFETY CLEAR" LED's ...:
What would cause my 4600 (4630/4640) Series operator to keep trying to open and squeal after opening to 90 degrees?
Resolution:
"Opening Force" adjustment could be set to strong (high). This adjustment is a turn pot adjustment which can be found on the controller. Try adjusti...:
What could cause a 9100 Series Benchmark operator not to open when the actuator is pushed?
Resolution:
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...:
Will the Falcon 8200 series operator burn up if someone tries to open it when the door is locked?
Resolution:
Any good secure setup and installation should be getting an open signal that has already gone through credential access first (ex……card reader, keypad, Key switch) and ignoring a locked door. ...:
Can a magnet, or sentronic device, be released and close the door from a button at a desk?
Resolution:
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiri...:
What does the 4040 SEL do for you?
Resolution:
The 3130SE, 4040SE, and the 4040SEH use the same length track. The 4040SEL track is longer.The SE/SEH (-3038) track is 22-3/4" long. It functions as a single point hold open, and can be set to hold...:
Why would a 8310-806K be used in conjunction with a 4600 that has a on/off hold open switch?
Resolution:
For wiring diagram see here. :
Is there a left hand hold open clip (block) for a 3130 series closer?
Resolution:
As of Feb. 8th, 2016- LCN launched a new HO feature (block) for all track closers, which is not handed. Part # for the Hold Open clip (block) is 3130-3054 and it also requires the...:
Can you replace a regular arm with a hold open with out moving the door closer?
Resolution:
Yes, as long as you stay with the like style arm. Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.:
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...:
What is a Senior Swing 9540 RF?
Resolution:
The Senior Swing Series used to have a 2 gearbox options, a "standard force" (15 lbs) and a "RF - reduced force" (11 lbs). In November 2009 RF option was eliminated and we made the standard gearbox...:
How much top rail is needed on a 4041 REG/PA (Rw/PA)?
Resolution:
To install a 4041/4040XP with Rw/PA or Hw/PA arm, you need a minimum of 5-3/8" top rail on the door, measured from the bottom of the stop. If the top rail is less than 5-3/8", you will need to use ...:
What are the 1460 closer arm options?
Resolution:
The 1460 Regular Arm part numbers are: Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish). Regular Arm with PA -- 1460-3077PA (must specify finish). Regular Hold Open Ar...:
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
Can you manually pull a 4040SE out of hold open?
Resolution:
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. :
Will a 4040 Hw/PA hold open at 180°?
Resolution:
The 4041 Rw/PA and the Hw/PA have the same template. The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...:
What causes am ME Series closer to creep shut (creeper)?
Resolution:
If an ME Series closer creeps shut or will not hold open, Verify proper voltage is being supplied to the closer, if correct Check the on/off switch. Verify the voltage on the 2 pin co...:
What would cause a 4040SE not to hold the door open?
Resolution:
A 4040SE would not hold the door open if it has : No Voltage or Improper Voltage. Check that the track has proper voltage going to it (24V AC/DC or 120V AC). If 120 volts is supplied...:
What would cause a 4111 HEDA to not hold open?
Resolution:
The correct method (process) for setting the hold open is: The 4110 HEDA arms are handed, verify correct hand arm. (RH or LH stamped on shoe bracket) Loosen the hold open nut at shoe bracket. ...:
How do I wire an EL device to normally hold open the latch and release it during a fire alarm?
Resolution:
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted. During a fire alarm, the contact will open, dropping...:
When did the 4111 Cush arms become non-handed?
Resolution:
This engineering change did affect the templating of the closer. The stop in the shoe is slightly larger than the original handed cush shoe. The new non-handed arm template locates the closer and s...:
What is the part # for the 4040 HCush arm?
Resolution:
The part number for the 4041/4040XP HCush arm is 4040XP-3049CNS.:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
When did we start shipping the Senior Swing, Benchmark, and Falcon operators with the ES Filter?
Resolution:
On the Benchmark, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit will hold it's...:
How do you adjust the hold open time on a 4600 (4630/4640) operator?
Resolution:
To adjust the hold open time on a 4600 (4630/4640) operator: Press the "MODE" button on the control box 1 time to get into programming mode. The "YELLOW" mode indicator LED next to "HOLD OPEN TI...:
What is the minimum and maximum PSI applied to a 4800 operator?
Resolution:
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...:
Which of the Pneumatic operators uses the same cylinder?
Resolution:
The 4840 and the 4810 are they only cylinders that can be interchanged, they use the same cylinder for their individual applications.: