Can the 214-KIL be ordered with different keyways?
Resolution:
No, but the cylinder can be replaced with the Schlage 23-013 or the Falcon A23165-02 (comes with Schlage "C" keyway standard). :
Is there a list for all of the UL listings for the Commercial Electronics?
Resolution:
Please click here to get document. :
What keyways are available with Primus?
Resolution:
Primus is available with the following keyway families: ClassicObverse (C, E, etc.) & Quad (WSTP, VTQP, etc.) EverestC, D, and B (B available in SL cylinders only) Everest 29S,T, and R (...:
What is the replacement for the Zero 919 continuous hinge?
Resolution:
The Zero 700 series continuous hinge is the replacement for the obsolete 919 hinge.:
What mortise cylinder cam does Baldwin 6000 series mortise use?
Resolution:
The Falcon mortise cylinder cams for use with Baldwin 6000 series are:Conventional cam 20069-000IC cam 12667-011:
Is there a chart that compares Schlage ND to competitor locks?
Resolution:
INTERNAL DOCUMENT ONLYPlease see here for chart comparison. :
Can the wired portion of a 679 DPS be used along with the magnet portion of a 7764?
Resolution:
It is not recommended as the magnet and switch are sold together since they are tested together. The different shape and positioning of the 7764 magnet may not allow the 679 DPS to work proper...:
How to change the Master Programming Code on a DKP-165
Resolution:
To change the master you must put the DKP-165 into program mode then press 10# new master # new master # done. If you...:
Can the PB405 be installed on/in 45-minute rated openings?
Resolution:
PB405 cannot be installed on any fire rated opening and/or door where people go through. The power bolt is not a life safety device and can fail and cause lockins or lockouts. :
In Engage audits, why does it come up with passage and success with no event data to it?
Resolution:
If the same User accessed the door multiple times in succession, the reporting data may remove the event info. That was intended to save processing time in the server. If thi...:
«