What are the latch requirements for a UL listed door?
Resolution:
Single-point locks and latches with 1/2-in. minimum latch throw are intended for single-swing doors, and latches with 3/4-in. minimum latch throw are intended for the active door of doors mounted i...:
Can the L9453 mortise lock be ordered with an indicator?
Resolution:
the L9453 lock can not be ordered with an indicator. The additional rotation of the inside thumbturn would cause a possible false reading on the indicator. :
What templating is needed when using a 2030 closer and tectus hinges?
Resolution:
Use the 2030 installation instructions for butt hinges and measure from the apparent centerline of the tectus hinge.:
What is the throw dimension on the LM9200 bottom latch?
Resolution:
The bottom door gap (door to floor or threshold) cannot be less that 1/8" and cannot exceed 3/4". :
Is there a retrofit kit for Von Duprin ALK alarm kit?
Resolution:
Yes, an ALK can be ordered as a kit and added to an existing mechanical exit device. The kit ships with the required request to exit switch, the ALK circuit board, and a device cover plate wi...:
How do I find a local locksmith or service person for my Allegion products?
Resolution:
At us.allegion.com, the home page has a tab at the top of page titled Locators. Click on that tab, then enter your zip code, click submit :
What is the difference between the "OLD STYLE" spring & rivet package and the spring & rivet package for the HL6?
Resolution:
The old style spring only has one coil, and the new spring has 3 or 4 coils.:
How do I achieve delayed egress and electric latch retraction with Allegion products?
Resolution:
How do I achieve delayed egress and electric latch retraction with Allegion products? The DE5300 system can be used to lock the opening down with mag locks and will allow delayed egress. ...:
What 6000 series electric strike will replace the Von Duprin 5100 ?
Resolution:
What 6000 series electric strike will replace the Von Duprin 5100? The 6211 is our preferred replacement for the 5100.:
Is the 499F strike hook required for maintaining the fire rating of the Von Dupirn 98/99 Fire Rated Rim exit device on a pair of doors with mullion?
Resolution:
Is the 499F strike hook required for maintaining the fire rating of the Von Duprin 98/99 Fire Rated Rim exit device on a pair of doors with mullion? Yes. :
«