What are Florida Building Code (FBC) Listings for Von Duprin exits?
Resolution:
We have FBC approvals for exits. See FBC listing number FL-14482. The link to the online directory is : https://www.floridabuilding.org/pr/pr_app_srch.aspx:
What A knob lock functions can the Levon lever be installed?
Resolution:
The Levon lever has limitations on where it can be installed on the A knob:Available on the inside and outside trim for the 10 and 40 functions.Inside trim only for 25, 30, 53, 70, 80, and 85 funct...:
Will a non Primus key operate a Primus cylinder?
Resolution:
Classic and a Classic Primus keys use different keyways, so just dropping the finger pins will not allow a Classic key to fit into the Primus cylinder.Everest keys are interchangeable as the keyway...:
What is the maximum voltage for the ND12, ND80 or ND96 electrified lock?
Resolution:
The maximum DC voltage for the ND12, ND80, ND96 electrified lock is 12vdc - 24vdc +10% or 10.8 TO 26.4vdc.:
Are the small hinge tension pins for the Ives 3SP1 spring hinge sold as a separate item?
Resolution:
The small pin for the 3SP1 holds tension on the spring hinge. The pins are not sold separately by Ives. Comparable pins (Metric 18-8 Stainless Steel Dowel Pins) may be pur...:
Can a standard RX switch (non chexit) be adjusted?
Resolution:
Yes. Step 3 on RX installation instructions show how this is done. Click HERE for instructions.:
Does Ives still offer a 820 push latch? If not, what is the replacement for it? If it is no longer in production, is it still under warrantee?
Resolution:
The 820 has been out of production since 2009, no longer under warrantee. The replacements are the CL11 and CL12 invisible latches. :
What is the overall length of the Ives 8371 pull with a 18" center to center?
Resolution:
Overall length is 22" with an 18" center to center pull.:
Does the Ives part number FBPART.1056 come with a mounting plate for the FB41T?
Resolution:
No.Use part number FBPART.1014 for the rub plate. :
Will the E376L-BE work with a 5547 device?
Resolution:
It will work, be mindful of the height from the finished floor. Please contact Allegion product support at 877-671-7011 if you have additional questions.:
«