Question
Answer
What is the locking time on the Schlage L9000 electrified locks?
Resolution:
Locking Time Cycle:Immediate locking since motor driven on the L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUDelayed 8-10 seconds due to pulsed signal for solenoid on the L9...:
What material is the ANSI strike on an NDE when supplied with the 10-130 strike?
Resolution:
The strike will be supplied in a brass or bronze material depending on the finish specified.:
Can you use the 2 3/8 latch from ND locks on CO locks?
Resolution:
They are the same...the only difference is the ones that come with CO locks have a UL sticker, whereas the ND ones do not.:
Can Schlage Multi-technology readers recognize Corporate 1000 – 48 bit?
Resolution:
**UPDATED** The new Si readers are able to read 48 bits and can be ordered with the NDEBSi, LEBSi or an Si reader for the AD series. :
Can AD locks be order with a split finish?
Resolution:
Yes. In the part number, first state the exterior and then the interior. Example: AD400-CY-KP-RHO-626-625…:
What is the part number for the ibutton reader with USB adapter?
Resolution:
48-539:
For a 600 series Push Button with the DA (delayed action) option, what is the time range for the delay?
Resolution:
It is adjustable from 0-60 seconds. :
Does the PIB300 connected to AD300 both require separate power supply?
Resolution:
They could be powered by same unit, if they are close enough. With data pair and power pair of wires the power supply can be at the PIB300 feeding both AD300 locks, as long as current sup...:
Can the 621 AL-EX-NS be field modified with P620022-1 (PB Sub Assembly DA Narrow)?
Resolution:
No, it has to be ordered with the DA function, not field install-able.:
What is the reason to wire daisy chain 2 AD300 to a PIB?
Resolution:
It is the suggested method of wiring the locks to the PIB per engineering. It will it work if you wire each lock directly to the PIB, but daisy chain is the preferred method. Make sure to addr...:
«