Can I use an AD or CO - 993 Exit Trim with a Von Duprin 98/99 Concealed Vertical Rod exit device on a wood door?
Resolution:
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit deviceĀ on wood doors.:
Will an AD or CO lock that has been toggled unsecure relock automatically at midnight?
Resolution:
If an AD or CO manually programmed lock is toggled unsecure / unlocked by a Toggle credential, it will not automatically relock when its real-time clock reaches midnight.:
What is the template for the 224HD TW8 continuous hinge?
Resolution:
Templates for 224HD TW8 continuous hinges areĀ 829431-00 for 83" & 85", 829433-00 for 95" & 829435-00 for 120" tall doors. Templates for 112HD TW8 continuous hinges are 829430-00 for 83" & 85", 82...:
Would there be an issue with 98/9947 NL-OP and retracting the rods with that 10' tall door?
Resolution:
No issues, will be slightly more difficult to turn the key than a 8' door. In general the NL/NL-OP can have increased force required to retract latches.:
Can 5100 electric strikebe used on fire rated door?
Resolution:
The Von Duprin 5100 electric strike is not for fire rated applications.:
Available kits to convert classroom mortise locks to classroom security locks.
Resolution:
Schlage has conversion kits to convert the classroom L/LV9070 to the classroom security L/LV9071 and the classroom holdback L/LV9076 to the classroom security holdback L/LV9077. The...:
Does Steelcraft offer the doors and frames galvanized or galvannealed?
Resolution:
Yes, Steelcraft does offer optional A60 and A40 Galvannealed, and G90 Galvanized steel on doors and frames. Galvannealed A60 and A40: A60 coating designation - optional on all doors and frame...:
Are 1 piece top rods available for a 24V or 25V device?
Resolution:
As of August 3rd, 2011 this is no longer an option.:
What are the door cores A, B, C, D, E & F per SDI 100?
Resolution:
These references are from an old and outdated SDI 100 specification. The new specification SDI 100 ANSI A-250.8 does not contain letter designations for core material. Core constructions designat...:
Can the KR kit be switched from a 7ft to 8ft mullion tube?
Resolution:
You can install the KR unit onto 8' mullion tube per KR Mullion Kit instructions.:
«