Question
Answer
Modifying the admin code on a DKP-NS
Resolution:
Locknetics DKP-NS - Modify or Change the Admin Code:
Removing all user codes for the DKP-NS
Resolution:
Locknetics DKP-NS - Remove All User Codes:
Changing the relock time delay on a DKP-NS
Resolution:
Locknetics DKP-NS - Setting Unlock/Relock Time:
Restoring the admin code for a DKP-NS
Resolution:
Locknetics DKP-NS - Restore Default Admin Code :
Does Allegion manufacture non-ferromagnetic maglocks.
Resolution:
No, we do not offer any non-ferromagnetic maglocks.:
On the NC450, is there a keeper that opens the strike?
Resolution:
No, there is not a keeper that opens, the keeper basically moves the ramp and the latch should push into the door to allow access. If the deadlatch is not pushed in, the latch will not push back in...:
How to tell if a PS902, 904,906 and 914 are working correctly?
Resolution:
There should be a green LED AC side and red LED DC side of the main board. You can see the green AC led with the box cover closed but have to open the cover to see the red LED for DC.:
Using a 900-4RL with an AO setting, how does this work?
Resolution:
For both sides to work together yes. Relay 1 actuates the locking device and 2 sends the dry contact signal to the AO. Relay 3 actuates the locking device on the second door and 4 sends the dry con...:
Can you program a toggle code into the DKP-NS or would you need to use a maintained closure on the remote release?
Resolution:
You can set the relock time delay to zero and it will be a toggle. Problem is that every code in that zone will be a toggle.:
What is the part number for a 620/631 solid red button with no writing on it?
Resolution:
P620091:
«