Answer
Is there an LCN surface mounted track closer that will swing 180 when mounted on push side of door?
Resolution:
There is no surface mounted track closer that can be mounted on the push side of the door that can be templated for 180 degree swing. Will need to go to a pull side mount track closer.:
How do you undersize a door with SOSS Hinges?
Resolution:
Each model of hinge is different. Locate the “G-Dimension” of the hinge model an add the latch side dimension. These 2 dimensions will give you the total amount to undersize the door.:
Do Falcon MA series locks have Florida Building Code (FBC) approval for Hurricane non-impact on pair doors?
Resolution:
MA Series Assembly Florida Building Code approvals for MA pairs with non-impactPair Flush Doors - FL10356.1Pair Glazed Doors - FL10356.4Pair Louvered Doors - FL10356.5:
How do you change the tailpiece orientation on a Schlage SFIC rim cylinder housing?
Resolution:
The Small Format Interchangeable Core rim cylinder from Schlage ships with the driver bar in the horizontal position. To change the bar to the vertical position, follow the following steps:Re...:
What is the ND55?
Resolution:
The ND55 is an Entrance lock with Automatic Unlocking with an outside indicator.Lever with key cylinder outside.Turn/Push Button Locking: Pushing and turning inside button locks the outside lever r...:
Can you order an un-match rod length on a pair of Flush Bolts?
Resolution:
The standard rod for a 12" distance from the top or bottom to the centerline of the faceplate is always provided with the metal door Flush Bolts.The optional Extension Rods are supplied as a separa...:
Can I add a cylinder to an L9040?
Resolution:
The L9040 (L283-132) lock case does not have a cylinder retainer assembly. They body can accept the cylinder but it will not be held in place due to the lack of a retainer.:
Can Falcon Conventional cylinders be order 0-bitted?
Resolution:
Falcon conventional cylinders can be ordered O-bitted and does not incur a charge.Small format cores are no longer available O-bitted.:
Does SOSS have a hinge for a 45-minute fire rated door?
Resolution:
For a 45-minute fire rated door we recommend using a Alloy Steel or Stainless-Steel hinge. These two substrates are rated 90 minutes in wood composite doors and up to 180 in metal doors.:
What is the replacement for the Dexter ED2000 Exit Device?
Resolution:
The Dexter ED2000 Grade 2 Exit Device was replaced by the ED1500 Grade 1 Exit Device several years ago.The changes necessary to get Grade 1 for the ED1500 are internal, therefore these two models l...:
«