What would cause a 4040SE not to hold the door open?
Resolution:
A 4040SE would not hold the door open if it has : No Voltage or Improper Voltage. Check that the track has proper voltage going to it (24V AC/DC or 120V AC). If 120 volts is supplied...:
What would cause a 4111 HEDA to not hold open?
Resolution:
The correct method (process) for setting the hold open is: The 4110 HEDA arms are handed, verify correct hand arm. (RH or LH stamped on shoe bracket) Loosen the hold open nut at shoe bracket. ...:
What does B80 or B140 indicate on an ME closer?
Resolution:
The "B" means "Bypass". The "80 or 140" is the degree of door opening from the fully closed position. "B80" means the hold open feature is bypassed (will not hold open) until the door is opened...:
Will a 4040SE open and hold at 180°?
Resolution:
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position. The 3130SE has an adjustable hold open position from 85° to 110° maximum. ...:
What is the part # for the 4040 regular arm?
Resolution:
The 4040 regular and hold open arms are different. You would have to get a different arm to convert from regular arm to a hold open function. 4040-3077 for a regular arm. 4040-3077L for a long ...:
When did we start shipping the Senior Swing, Benchmark, and Falcon operators with the ES Filter?
Resolution:
On the Benchmark, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit will hold it's...:
What could cause a 9100 Series Benchmark operator not to open when the actuator is pushed?
Resolution:
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...:
How to adjust a 4010 hold open arm?
Resolution:
The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...:
What could cause the Von Duprin EL solenoid not to hold when mechanism cover plate is slide over the solenoid?
Resolution:
If mechanism cover plate causes the EL solenoid to drop when slid over the solenoid, the solenoid plunger requires adjustment. You must lengthen the rod by turning the hex nut in front of the plun...:
What causes am ME Series closer to creep shut (creeper)?
Resolution:
If an ME Series closer creeps shut or will not hold open, Verify proper voltage is being supplied to the closer, if correct Check the on/off switch. Verify the voltage on the 2 pin co...: