will power boost come on if operator is not actuated
”
RELATED FAQS
Question
Answer
What is power boost on a Senior Swing or Benchmark operator?
Resolution:
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before co...:
Does a 4600 Series operator come with actuators?
Resolution:
Actuators are not included with a 4600 Series operator. Due to the numerous styles, they always need to be ordered separately.:
How do I get a Size 1 (ADA) closer to close against air pressure?
Resolution:
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...:
Why would an LCN 8310-865 RF Receiver have a flashing "RED" light?
Resolution:
When the "RED" LED on the 8310-865 RF Receiver is blinking, it is receiving an RF signal (interference) from a non programmed device. When receiving this type of signal, it will not ...:
What would cause a Senior Swing to open too far?
Resolution:
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...:
Does Falcon provide an On/Off switch for the 8200 series operator?
Resolution:
The Falcon 8200 operator is not available with a factory supplied on/off switch. If required, it must be supplied by others.:
Can you use a Senior Swing controller as a replacement for an obsolete Mid Swing controller?
Resolution:
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box...:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
Why would a Falcon 8200 Series operator be blowing the fuse?
Resolution:
If the Main AC fuse is blowing, the control box is defective and needs to be replaced. The "Main Fuse" is a (5x20MM) 1 Amp Slow Blow fuse. If the 12VAC fuse is blowing, verify they are not trying...:
What are the power requirements of the 4600 series operator?
Resolution:
The 4600 series operator requires a 120 VAC @ 1.5 Amp power input to be field connected. Hardwiring is always recommended, but a "plug-in" line cord can be installed (by others) with the proper cor...:
How do I get service on my Astro Swing operator that isn't working properly?
Resolution:
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...: