 Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached 6300 Template & I...
Hinge Spacing: All 4 1/2" and 5" butt hinge spacing 1. Opening heights 3'0" through 4'11 15/16" (one pair butt hinges) from under head CL 9 3/4" (top of door 9 5/8") from bottom of frame ...
Hinge Backset: On the frame = 5/16" On the door = 1/4"
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening ...
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the sa...
 See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
There is no template for 996L-DT for wood door. You will need to use the 996L-DT installation instruction or 996L-DT metal template. See attached instruction/template 996L-DT instruction/template.
Please visit the Schlage Residential website (FAQ / Knowledge Center) for all product and Customer Care information.Click on the following to link directly to the Residential Product...
Please contact the Allegion Product Support Team on all questions or inquiries pertaining to hardware finishes warranties. Please send an e-mail to the applicable Product Support team:Closers_TechP...
Click on the applicable Schlage G Series link below for template information. Wood Template 1 1/8" x 4 1/4" Radius Wood Template 1 1/8" x 4 1/4" Square Wood Template 1 1/4" x 8"Metal Templ...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
The LCN 6030 is a Double Acting (or dual action) closer. Requires a "Cased Open Frame" - that means no stops formed in the frame.
Information for CISA locks, cylinders and hardware is not available in Knowledge Center. For all information, please go to Allegion's CISA home page for all information.
The American National Standards Institute (ANSI) and Builders Hardware Manufacturers Association (BHMA) have developed durability, strength and performance standards for every type of door hardware...
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
Panic Hardware and Fire Exit Hardware are two different types of exit devices, and the proper selection is determined by code requirements. Panic Hardware is an exit device which is tested for u...
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device.  There are some internal parts that may be different and the method it is secured to the d...
The hole should be drilled in the field once the end cap is located on the door.  It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
An Astragal is an applied molding attached most commonly to the meeting edge of doors to: Protection against weather conditions Minimize the passage of light between the doors Retard the passa...
All hardware options (available on standard door) are available on GrainTech® doors. Available hardware are covered in the Steelcraft Price Manual. GrainTech® doors can be prepped for the Von Dupr...
Attach is the instruction and template for 237L device, 237 Instructions.
CO-100 now allows the PIN code length to be changed manually.  Each CO100 has a label that indicates its firmware revision.  Firmware revision 2.5.0 or higher support these...
CO-100 PIN length can range from 3 digits to 6 digits with firmware version 2.5.0 and higher.
Procedure to change PIN length: 1. Press {programming code (default is 97531)} then {*}.2. Press {99} then {*}, to enter Special Function Length Menu.3. Press {4} then {*}, to enter Pin Length M...
CO-100 now has NEW lock status reporting capabilities. Battery status, firmware version, hardware version and PCB serial number. See instructions below for these status menus.
The following items are needed for Spec Writers to write a door and hardware specification  Building code being used Occupancy type or types Occupancy load for any rooms or areas of ass...
See the installation instructions 718 for -C devices.
Templates for current 718 series trim can also be found on Falcon website
GrainTech® is a Steelcraft door option which provides a wood grained pattern which is embossed into both face sheets of the door. GrainTech doors are factory stained and top coated with a cle...
Delayed egress hardware prevents a door from being opened from the egress side, usually for a period of 15 seconds. This type of device is often used to prevent theft, while maintaining life safety...
 Click Here to view the Hollow Metal or Wood Door Templates for Von Duprin devices   The E996L trim and RX98/99 devices  use the standard 996L and 98/99 templa...
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, glass light designs and hardw...
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...
Those holes are for mounting the coordinator mounting bracket itself.  The brackets must be drilled and tapped for the hardware you are mounting to them.
The CS210 templates can be found at schlage.com.  Click here to find the templates.
 Cam Lift Hinges are specially designed hinges used mainly on acoustical door assemblies. The Cam Lift Hinge lifts the door during its travel and seats the door bottom for a pos...
Allegion does provides professional support to Architects and Design Professionals. For information related to specification development and support, Website for Architects and Design Professiona...
The NL-OP function for 25-C uses the 718C trim, so template T-2211 for metal doors and W-2211 for wood doors for 718 trims prior to 2/28/2011. T-2211 for trims prior to 2/28/2011 W-2211 for...
Grouting frames is: A process done in the field during hollow metal frame installation  The internal cavity of the frame is fill with masonry or mortar It is intended to mainly provide ...
Allegion provides professional access control support to Security Consultants and Security Integrators.  For information related to specification development and support,Access Contro...
No actual templates exist for this hardware. This hardware is currently only available for use on the Steelcraft Paladin series door and frame assembly and is sold as a complete package with the lo...