What is the difference between the Ives 482B and the 482A door guards?
Resolution:
The difference between the Brass version 482B and the Aluminum version 482A is the size and design as well as the base material and available accessories. The Brass version 482B comes w...:
What is the Buy American Act (BAA)?
Resolution:
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...:
What maintenance is required for an LCN closer?
Resolution:
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments. Monthly, quarterly, and annual visual inspections are recommended for Fire/...:
Are there any instructions for Von Duprin device maintenance?
Resolution:
Please see the Maintenance Kit Manual for information on device lubrication as well as complete breakdowns and parts lists for Von Duprin exit devices.Exit devices and latc...:
What is the Ives invisible latch replacement for the Glynn Johnson AA, BB and AP2 latches?
Resolution:
The Ives version is the same as old Glynn-Johnson versions.:
How should I clean a biometric hand reader?
Resolution:
The only routine maintenance required on a biometric hand reader is cleaning. The platen surface upon which the hand is placed, the side mirrors, and the overhead window should be cleaned with rea...:
Does Ives offer a 296G Flush Bolt?
Resolution:
The 296G is is not a model number but rather the UL listing number. This listing would be on many Ives Flush Bolts including; FB30 and FB40 series Automatic Flush Bolts FB50 and FB60 ...:
Are Ives pulls ADA compliant?
Resolution:
8103EZ and 9103EZ have 2 1/2" clearance the other pulls have 1-1/2" clearance. Check with your local code for clearance required.:
What is the part number for the Von Duprin maintenance kit?
Resolution:
Von Duprin has a maintenance kit part number 050046-00 and maintenance instruction, part number 941079-00 for 98/99 series devices. There are some common parts between 98/99 series and 22...:
What tools and pinning kits are required to service Everest 29 keys and cylinders?
Resolution:
The current tools, pinning kits and key originating machines for all Schlage Everest full size cylinders and small format cores are the same used on Everest 29.:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
How does Cache mode work on AD400 and AD300 locksets?
Resolution:
An AD400 granting credentials access in “cache mode” will blink the Schlage with the normal green LED, followed by a brief red Schlage LED flash, indicating no RF communication and access was grant...:
What is the part number for the rubber tip for an Ives hinge pin door stop?
Resolution:
Model 69 the part number is 09-310Model 70 & 73, the part number is WSPART.1075:
Where is the catalog information and specifications on the Ives edge guards?
Resolution:
Information for Ives edge guards can be found on pages B51-B53 of the Ives Catalog linked here, and in the edge guard ordering guide linked here.:
Are flush bolts available on the inactive leaf of hurricane double doors with either FBC or NOA approvals?
Resolution:
Ives SB360 surface bolt at top and bottom are the only flush bolts approved for use on H-Series hurricane FBC or NOA applications? The only approved latching hardware for inactive leaf of pairs w...: