What is power boost on a Senior Swing or Benchmark operator?
Resolution:
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before co...:
What causes a Senior Swing door to hang open and not close?
Resolution:
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...:
What would cause a Senior Swing to open too far?
Resolution:
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...:
Why would a Senior Swing door slam shut?
Resolution:
The Senior Swing has a built in circuit that controls closing speed through the motor. If the door is slamming, there must be a broken gear in the gearbox and the gearbox will need to be replaced.:
Where does the 8310-877 safety sensor attach to the Senior Swing controller?
Resolution:
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...:
Can you power an electric strike or maglock from the 9500 Series Senior Swing?
Resolution:
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable.For Current Sr Swing control boxes with ID# 72940 on th...:
How do you install a Senior Swing 9540 on one leaf of a double door?
Resolution:
Surface Mounting - A 9542 HDR2 (Double Door Header) and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can then be installed on the inactive leaf....:
How do you install the LCN 9530 Senior Swing (STD) pull arm?
Resolution: