roller latch resistance

RELATED FAQS

Question
Answer
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.  For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...
A lock is any device which prevents access or use by requiring special knowledge or equipment. Mechanical locks are mechanical devices which secure an opening by keeping a door closed until a relea...
Deadbolt Locks (Deadlocks): a lock with a bolt which requires a deliberate action to extend and which resists end pressure in the unlocking direction when fully extended Medium, high to extra he...
For Motor driven Chexit devices shipped from the factory after 8-24-2015, the Chexit Secure Relay Contacts( white and violet wires) change state to signal the device is not secure. Check the f...
For Solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the following could cause the device not to provide delay egress:Measure the voltage between green and orange wires o...
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...
Schlage does not test their locks for ballistics or bullet resistance.
VISIT US.ALLEGION.COM/EL-SUPPORT FOR TROUBLESHOOTING VIDEO, DOWNLOADABLE GUIDE, AND INSTALLATION INSTRUCTIONS(For best viewing, use Chrome or Firefox browser.)ALLEGION EL SOLENOID ELECTRI...
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
Part numbers listed below: 2030-3071 cylinder assembly includes the closer cylinder and finish plate.  2030-3971 is the cylinder only. 2030-3002 is the finish plate. 2030-3077T is ...
The replacement arms for the older handed 4010SE/4110SE closers would be ordered as: 4040SE-3077T x ST-3035 for a RH arm. 4040SE-3077T x ST-3035-1 for a LH arm. 
Product shipped on or after Feb. 8th, 2016 The "3034" and "3034H" are internal part designation that LCN uses to specify regular (3034) and hold open (3034H) roll...
On Feb 8th, 2016 - LCN launched the redesign of the Hold open clip which changed multiple components of our Track style closers, including the roller, track, hold open clip, and bumper. 
Strike or ridged plate with ridges part number is 970323622.
The best way to test the Von Duprin EL solenoid is with an ohm meter. You must test both coils to make sure the solenoid is good. The coil has three wires; green, yellow, and orange. The green...
Only applicable for solenoid driven Chexit devices shipped from the factory prior to 8-24-2015; Chexit solenoid coil resistance between the green and orange wires is 110-140 ohm and betw...
To check an ME or SE solenoid Unplug the solenoid from the circuit board. Measure resistance across the 2 pin of the solenoid connector. The solenoid resistance should read: 24 volt solenoi...