Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
roller latch resistance
”
RELATED FAQS
Question
Answer
What special template (ST) is used with the 2030 closer and a low profile track and roller?
Resolution:
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track. For a top rail less than 1-3/8" and as narrow as 1", you could use the l...:
Does Falcon have a breakaway lever trim feature on mortise locks?
Resolution:
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...:
What is a mechanical Lock?
Resolution:
A lock is any device which prevents access or use by requiring special knowledge or equipment. Mechanical locks are mechanical devices which secure an opening by keeping a door closed until a rel...:
What is a deadbolt?
Resolution:
Deadbolt Locks (Deadlocks): a lock with a bolt which requires a deliberate action to extend and which resists end pressure in the unlocking direction when fully extended Medium, high to extra he...:
What would cause the Von Duprin delay egress Chexit device not to provide delay egress?
Resolution:
For Solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the following could cause the device not to provide delay egress:Measure the voltage between green and orange wires o...:
How do you test a Falcon 24 or 25 Series EL solenoid?
Resolution:
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...:
Does Schlage make a level 4 bulletproof lock?
Resolution:
Schlage does not test their locks for ballistics or bullet resistance.:
EL Device Troubleshooting Guide
Resolution:
VISIT US.ALLEGION.COM/EL-SUPPORT FOR TROUBLESHOOTING VIDEO, DOWNLOADABLE GUIDE, AND INSTALLATION INSTRUCTIONS(For best viewing, use Chrome or Firefox browser.)ALLEGION EL SOLENOID ELECTRI...:
Does a SEH require a door closer?
Resolution:
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...:
What is the part number for the plate and the 2030 cylinder?
Resolution:
Part numbers listed below: 2030-3071 cylinder assembly includes the closer cylinder and finish plate. 2030-3971 is the cylinder only. 2030-3002 is the finish plate. 2030-3077T is ...:
Can I get a replacement arm for an old 4110SE closer?
Resolution:
The replacement arms for the older handed 4010SE/4110SE closers would be ordered as: 4040SE-3077T x ST-3035 for a RH arm. 4040SE-3077T x ST-3035-1 for a LH arm. :
Is there an identification chart for all the different rollers that LCN has?
Resolution:
Product shipped on or after Feb. 8th, 2016 The "3034" and "3034H" are internal part designation that LCN uses to specify regular (3034) and hold open ...:
What is the part number for the "ridged" or "strike" plate on the 299 roller strike?
Resolution:
Strike or ridged plate with ridges part number is 970323622.:
What is the best way to test the Von Duprin EL solenoid?
Resolution:
The best way to test the Von Duprin EL solenoid is with an ohm meter. You must test both coils to make sure the solenoid is good. The coil has three wires; green, yellow, and orange. The green...:
What is the solenoid coil resistance on the Chexit solenoid?
Resolution:
Only applicable for solenoid driven Chexit devices shipped from the factory prior to 8-24-2015; Chexit solenoid coil resistance between the green and orange wires is 110-140 ohm and betw...:
How do you check an ME or SE solenoid?
Resolution:
To check an ME or SE solenoid Unplug the solenoid from the circuit board. Measure resistance across the 2 pin of the solenoid connector. The solenoid resistance should read: 24 volt solenoi...: