rim device latch fully retract

RELATED FAQS

Question
Answer
The part number for 88 rim end case spring is 090003-00 (PKG of 2) or 090080-00 (PKG of 10) and latch tail spring is 050393-00 (PKG of 10).
Using the key from the pull side of the door does not retract the latch bolt on a rim or vertical rod chexit device.
CX98/9975 mortise devices will retract the latch bolt when the key is used on the pull side of the door.
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device.  Be sure this screw is installed- Exit hardware and strike must be properly mounted ...
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts.  This may NOT be used on Fire Rated openings.
Bad dogging hook on the dogging assembly could cause the 33A/35A and 98/99 exit device latch bolt not to retract completely.
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...
VISIT US.ALLEGION.COM/EL-SUPPORT FOR TROUBLESHOOTING VIDEO, DOWNLOADABLE GUIDE, AND INSTALLATION INSTRUCTIONS(For best viewing, use Chrome or Firefox browser.)ALLEGION EL SOLENOID ELECTRI...
HH hurricane rated devices usually have a deferent strike and fire rated mullion. Standard 98/99 series exit devices can be converted to HH by changing the strike and mullion on pair of doors. ...
The 98/99 rim device can be converted to double cylinder 98-2 or 99-2. Double cylinder features an inside key cylinder which locks or unlocks the outside trim (Classroom Function) and an outside c...
A thumbpiece, knob or lever trim left in the unlock position would be locked when the Chexit is armed and unlock when the Chexit device is disarmed. To keep the outside trim in the lock p...
The 98/99 rim device can be converted to double cylinder 98-2 or 99-2. Double cylinder features an inside key cylinder which locks or unlocks the outside trim (Classroom Function) and an outside...
Yes the Von Duprin QEL exit device retracts the latch bolt and pushpad. Pushpad and latch bolt stay retracted as long as power is applied to the QEL exit device.
The Von Duprin Chexit device does not have electric latch retraction feature.
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping...
The Von Duprin PS914 power supply must be used on the EL devices with either the 900-2RS or 900-4RL option board since the EL devices requires power supplies set at 24VDC to be able to provide the ...
  You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board  will power 1 or 2 devices that do not require timing from pow...
If the NL screw on the 99 device has been removed the Trilogy lock will not retract the latch.
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. 
There is no EL conversion kit for a 2390, the device will need to be replaced.
 Electric latch retraction, EL, devices are only available in 24VDC.
You can not use these options together on the same device per the following reasons: QEL/EL device retracts the latch bolt of the exit device allowing entry. CX (Chexit) device ...
  Pushing on the push  bar or activating the EL/QEL or the trim on Von Duprin XP98/99 exit device does not retract the latch, it releases the latch only. Door must be pushed or pulled when device o...
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate baseplate.&n...
  For Product Shipped Prior to August 2012 using the old (black) potted module: a.       0-100 ft 14 gauge wire b.      0-200 ft 12...
 
Electric Latch Retraction(ELR) option for the 19 Series was discontinued in December of 2006.
Yes, fire rated exit devices can have electric latch retraction.  However, the devices must be tied into a fire alarm system to remove power from the units so the doors will be latched in the ...
One of the following items may cause the EL1490 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...
The LX switch is not available with Von Duprin rim and vertical rod Chexit devices. If using a mortise Chexit device the SS7500 mortise lock would provide a LX latch bolt monito...
Finish is not specifically stated as being covered under warranty as it is covered under defects in material and workmanship.  EXCEPTION: There is no finish warranty for Falcon products. ...
Falcon lock warranty statementIves warranty statementGlynn-Johnson warranty statementLCN closer warranty statementSchlage warranty statementSteelcraft warranty statementVon Duprin warranty statement
Please contact the Allegion Product Support Team on all questions or inquiries pertaining to hardware finishes warranties. Please send an e-mail to the applicable Product Support team:Closers_TechP...
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...
The following items may cause the exit devices top latch from being held in the retracted position. 1. The top or bottom rods are out of adjustment. 2. The top latch hold back...
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...
The following list explains the differences between the Von Duprin 47 and 48 latch assemblies. The 47 top and bottom latches have 5/8" throw latchbolts. The 48 top and bottom latches have 3/4" ...
 HD-EL (Hex Dogging Electric Latch Retraction) solenoid and plunger can be replaced with standard EL solenoid and plunger on non fire rated exit devices, but this should not be used on a daily basi...
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
Most likely need to length the top rod so latch can engage it's internal latch retention state. See 2390 Instructions for adjusting rod lengths.
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.
If the 912L was shipped after February 28,  2011, Check the installation instructions, step 3 to be sure all parts are installed on the trim correctly, even if the trim was received in th...