power supply for magnetic lock
”
RELATED FAQS
Question
Answer
Why is a 5100 electric strike clicking but not locking?
Resolution:
Follow the steps below to troubleshoot the problem. Measure the voltage at the electric strike. If the strike is FSE and not locking there should be no voltage at the strike and if it is FS there ...:
Why is the battery draining so quickly on an AD-Series lock with a Keypad ONLY (KP) credential reader?
Resolution:
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.:
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
What took the place of the Von Duprin 873-DE option board?
Resolution:
The delay egress is controlled in the exit device (Von Duprin Chexit), the magnetic lock, or other locking device.:
What current should an AD-Series or CO-Series lockset draw while in its low power "Sleep" mode?
Resolution:
Use a multi-meter in series with the batteries to measure battery current. Be sure your multi-meter can accurately measure very low current, in the micro-amp range. See the attached Technical Not...:
Will mag locks operate with voltage ranges between 12vdc and 24vdc?
Resolution:
The entire series of mag locks that Schlage provides advertises 12vdc or 24vdc because they will automatically determine what voltage is being used and switch the internal circuitry based on that v...:
What is the Buy American Act (BAA)?
Resolution:
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...:
What power supply do I use with an L9000 electrified L lock?
Resolution:
Applies to L9080EL/EU, L9082EL/EU (Discontinued) The Schlage L9080 EU/EL and L9082 EU/EL require 24 VAC/VDC with a peak current of 1.3 Amps at 5 to 10 second intervals and a holding ...:
How do I program my device?
Resolution:
The programming processes for Allegion devices can be both product and features specific. Some products programming processes are electronic in nature, others are physical in nature. &nb...:
Does the 9540 Senior Swing need a separate relay board for wiring to electric locks?
Resolution:
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.:
What is the low battery threshold for the AD and CO Locks?
Resolution:
CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...:
How do I change an AD-Series lock to a different AD-Series lock type?
Resolution:
Re-classing is the process by which an AD-Series device is able to change its lock type. The AD-Series has a modular architecture and a major benefit of this type of architecture is that it allows ...:
Will a PS902 power my mag lock and my DE5101?
Resolution:
This is possible as long as the total current draw does not exceed the 2 amp capacity of the PS902 power supply. The Schlage Electronics 320, 350, or 390 maglock must be used with a DE5101 and th...:
Can the AD-Series and CO-Series magnetic card credential readers be set to read data from different magnetic card tracks?
Resolution:
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...:
Does Falcon offer a Delayed Egress exit device?
Resolution:
There is not a fully self-contained delayed egress like a Von Duprin Chex-It device but the Falcon RX-24 or RX-25 Series can perform a delayed egress by using the DE5300 controller, power supp...:
What power supply is needed for EL devices?
Resolution:
You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board will power 1 or 2 devices that do not require timing from pow...:
What wire gauge and run is recommended for Von Duprin electric latch retraction EL device?
Resolution:
:
Upgrading any AD-Series lockset to an AD300 - power restrictions
Resolution:
Connect 12VDC or 24VDC power supply to the AD300 lock before attempting HHD communication.:
How is the DE 5101 used?
Resolution:
DE5101 is a delay egress controller to provide a delay to open the door. It is used with Schlage Electronics M320, 350, or 390 24VDC magnetic lock, push bar with IR panic with a request to exit swi...:
Can we run both mag locks and EL devices from the PS 914?
Resolution:
It requires 900-4RL and 900-FA option boards to release the mag locks when a fire alarm is activated. Specify PS914 x 900-4RL x 900-FA.:
Maglock Making a "Buzzing" Noise
Resolution:
: