Are the 2313ME, 4313ME, and 4413ME LCN models still available?
Resolution:
The only spring size available is a size 4 (2314ME, 4314ME, 4414ME) which has a stronger spring to help insure that the door will close in a fire situation.:
Does the old style 4030 have the same templating as the new style 4031?
Resolution:
The old 4030 series was: Handed Mounted regular arm hinge side. Had sized springs, were not adjustable. The 4033 is an obsolete closer. If required, handing can be verified by looking at ...:
What would replace a 4013 closer?
Resolution:
The 4010 Series "fixed" sized springs are no longer available. The 4010 Series closer are now available as a 4011 and a 4016. The 4011 is an adjustable spring closer for sizes 1-5. The 4016 is stil...:
Is the 4041/4040XP and the 4040SE cylinder body the same?
Resolution:
The 4041/4040XP and 4040SE closers cylinders are "NOT" the same. The 4041/4040XP cylinder has an adjustable size 1-6 spring. The 4040SE cylinder has an adjustable size 2-4 spring. The 4041/404...:
CLOSING FORCE
Resolution:
Force, Spring, Spring Size, Closer Size:
Can I get a Senior Swing with a reduced opening force gearbox?
Resolution:
The older model Senior Swing came with 2 spring options. The "standard force" spring required 15 lbs of manual opening force, and reduced force "RF" required 11 lbs of manual opening force. All S...:
Is the 2030 spring adjustable?
Resolution:
All the 2030 series closer have a fixed spring sizes. Example -- a 2031 has a size 1 spring, a 2302 has a size 2 spring, 2033/2034/2035 etc. All the 2030 series closer are shipped a...:
How do you identify what size a 2030 closer is?
Resolution:
The Date Code and Closer Size are stamped in the backside of the closer body. These stamps will be on a smooth machined surface of the cylinder.Closer Size:If the number is "1", the...:
Is the spring torque on 3SP1 hinge adjustable?
Resolution:
Yes, the spring torque on 3SP1 butt hinge is adjustable. See the 3SP1 instructions: :
How do you adjust a door closer?
Resolution:
How to: What are the steps to adjust a door closer? Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All cl...:
Is there adjustment limits on the regulation valves of LCN manual closers?
Resolution:
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valv...:
What is the opening force of a 4600 Series (4630/4640) operator when used manually?
Resolution:
The manual opening force on a 4630/4640 will be approximately 8.5 lbs to 14 lbs depending on the spring setting.:
What is the rough opening in walls for frame installations?
Resolution:
For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...:
What are the 1460 closer arm options?
Resolution:
The 1460 Regular Arm part numbers are: Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish). Regular Arm with PA -- 1460-3077PA (must specify finish). Regular Hold Open Ar...:
How do you order a 4110 hold open spring cush arm only?
Resolution:
The 4110 hold open spring Cush (Spring H Cush) arm part number is 4110-3049SCNS.:
What is a Senior Swing 9540 RF?
Resolution:
The Senior Swing Series used to have a 2 gearbox options, a "standard force" (15 lbs) and a "RF - reduced force" (11 lbs). In November 2009 RF option was eliminated and we made the standard gearbox...:
Do Von Duprin Exit devices meet the 5 pound force requirement for opening an ADA handicapped door opening?
Resolution:
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device. Maximum allowed force to retract the Von D...:
OPENING SIZE
Resolution:
Nominal Opening Size:
SPRING HOLD-OPEN CUSH ARM
Resolution:
SHCUSH,:
OPENING FORCE
Resolution:
ADA, ada Code, Spring Tension, Spring:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
What is clear opening width?
Resolution:
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb. &nbs...:
Will the new concealed vertical cable system work with any door height?
Resolution:
:
What is a cylindrical lock?
Resolution:
Cylindrical Locks: a bored lockset whose latch or bolt locking mechanism is contained in the portion installed through the cross-boreMedium, high to extra heavy dutyCommercial, multi-family and ins...:
What is the difference between a 1460 and a 1461 closer?
Resolution:
As of today the 1460 is the closer "series number", and 1461 is the closer "model or ordering # ". Both numbers represent the same door closer, there is no difference.:
What is the part number for the plate and the 2030 cylinder?
Resolution: