old sr swing controller fuse
”
RELATED FAQS
Question
Answer
What is a 85445-900?
Resolution:
The 710095-00 (85445-900) and 84570-900 are the older Sr. Swing analog (non-digital) control. It is replaced by the current Sr. Swing digital control box. If you need to replace an old ...:
How do you get the digital read out to light up on the Senior Swing Control Box?
Resolution:
There is a total of 4 red buttons on the front of the Senior Swing control box. To turn on the display, press and hold any 2 of the 4 red buttons at the same time for approximately 3-5 seconds. Y...:
What is the part number for the Senior Swing control box?
Resolution:
The Senior Swing Series changed to the "Digital" control box in Sept. of 2006.:
Can you use a Senior Swing controller as a replacement for an obsolete Mid Swing controller?
Resolution:
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box...:
Where does the 8310-877 safety sensor attach to the Senior Swing controller?
Resolution:
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...:
What wires are the activation inputs for the Senior Swing?
Resolution:
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. ...:
What would cause a 4600 (4630/4640) to keep blowing fuses as soon as the 120VAC cable is plugged into control box?
Resolution:
The main AC fuse would blow if there is a direct short across the AC line. This could be caused by a:1. Defective I/O PC Board (-3180) To check - unplug the control box AC power cable (2 wire) fro...:
Is the 9500 Series Senior Swing handed?
Resolution:
The Senior Swing "control box" is not handed. All Senior Swing motor "gearboxes" are handed, both the 2800 Series concealed and 9500 Series surface mounted operators. The 2800 Series "concealed a...:
Can you replace the old 9100 Benchmark II controller with the new 9100 Benchmark III controller?
Resolution:
The current Benchmark III controller (9130-3462, 9140-3462) is a direct replacement for the older Benchmark II controller.:
What could cause the fuse to blow in a PS873 power supply?
Resolution:
Following could cause the fuse to blow in Von Duprin PS873 power supply. PS873 power supply provides 2AMP at 24VDC or 4AMP at 12VDC. If this limit is exceeded the fuse will blow in the power sup...: