Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
lock out switch
”
RELATED FAQS
Question
Answer
Where does the hold open switch on the 4630 / 4640 wire into on the 1-24 single terminal strip?
Resolution:
The 4600 hold open switch (for the new 1-24 single terminal strip I/O board) wires into terminals 2 and 6 or 4 and 6.:
Why would a 8310-806K be used in conjunction with a 4600 that has a on/off hold open switch?
Resolution:
For wiring diagram see here. :
Does Falcon provide an On/Off switch for the 8200 series operator?
Resolution:
The Falcon 8200 operator is not available with a factory supplied on/off switch. If required, it must be supplied by others.:
How do I program my device?
Resolution:
The programming processes for Allegion devices can be both product and features specific. Some products programming processes are electronic in nature, others are physical in nature. &nb...:
Does the 9540 Senior Swing need a separate relay board for wiring to electric locks?
Resolution:
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.:
Is there a way to clone a failed PIM400 so it could be replaced without having to re-link associated locks?
Resolution:
It is currently not possible to clone an AD-Series PIM400.:
What versions of Microsoft Windows are compatible with Schlage Express version 4.4.2?
Resolution:
Microsoft Windows 8, 7, Vista, and XP: Home, Basic, and Starter versions are not compatible with Schlage Express. What versions of Microsoft Windows are compatible with Schlage Express v...:
AD changing Function in the field
Resolution:
-On the AD series offline locks only you can change the lock function from Classroom/Storeroom to a Privacy, office or apartment function out in the field. - This is done via the HHD/SUS using...:
Why can't I LINK my AD-Series lock?
Resolution:
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...:
Why does the Schlage button light up “Green” when I open the door?
Resolution:
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...:
What drains the AA batteries on an AD-Series lock?
Resolution:
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1) One the four (or eight) AA was inserted reversed and the rese...:
What firmware does my CO-100 lock have?
Resolution:
CO-100 now has NEW lock status reporting capabilities. Battery status, firmware version, hardware version and PCB serial number. See instructions below for these status menus. :
Can you mount a 4011 as a parallel arm like the 4111?
Resolution:
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...:
What actuators can be used on the 8310-866 Bollard post?
Resolution:
The LCN Bollard post (8310-866) only accepts the "square" actuators (no round actuators). The size of the Bollard post is 4” X 6” X 36”. Acceptable actuator part numbers are: Hard Wired - 831...:
Does a SEH require a door closer?
Resolution:
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...:
Will a new RF "programmable" transmitter work with an older RF receiver that has "dip switches"?
Resolution:
The newer "programmable" RF transmitters/receivers will not work with the older "dip switch" transmitters/receivers. The frequency and coding are different.: